Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System): B1411; Room Temperature Sensor Circuit; 2019 - 2022 MY Corolla Corolla Hatchback GR Corolla [06/2018 - 09/2022] |
DTC
|
B1411
|
Room Temperature Sensor Circuit
|
DESCRIPTION
The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B1411
|
Room Temperature Sensor Circuit
|
Open or short in room temperature sensor circuit
|
-
Cooler (room temp. sensor) thermistor
-
Harness or connector
-
Air conditioning amplifier assembly
|
Memorized
(4 sec. or more)*
|
-
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
HINT:
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411 may be stored even though the system is normal.
WIRING DIAGRAM
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Room Temperature Sensor
|
Cooler (room temp. sensor) thermistor
|
Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
|
Actual cabin temperature displayed
|
Cooler (room temp. sensor) thermistor circuit malfunction
-
When open circuit: -6.50°C (20.30°F)
-
When short circuit: 57.25°C (135.05°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Room Temperature Sensor
|
OK:
The display is as specified in the normal condition column.
NG
|
|
|
2.
|
INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
|
(a) Remove the cooler (room temp. sensor) thermistor.
Click here
(b) Inspect the cooler (room temp. sensor) thermistor.
Click here
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
I36-1 - I48-5 (TR)
|
Always
|
Below 1 Ω
|
I36-2 - I48-3 (SG-1)
|
Always
|
Below 1 Ω
|
I36-1 or I48-5 (TR) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
I36-2 or I48-3 (SG-1) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|