Last Modified: 01-30-2024 6.11:8.1.0 Doc ID: RM100000002EWF6
Model Year Start: 2024 Model: RAV4 Prod Date Range: [10/2023 -           ]
Title: A25A-FKS (BATTERY / CHARGING): CHARGING SYSTEM: ON-VEHICLE INSPECTION; 2024 MY RAV4 [10/2023 -        ]

ON-VEHICLE INSPECTION

PROCEDURE

1. CHECK BATTERY CONDITION

NOTICE:

If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.

(a) Check the battery for damage or deformation. If severe damage, deformation or leakage is found, replace the battery.

(b) Check the voltage.

(1) Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.

(2) Measure the battery voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Condition

Specified Condition

Positive (+) terminal - Negative (-) terminal

20°C (68°F)

12.3 V or higher

If the result is not as specified, recharge or replace the battery.

2. CHECK BATTERY TERMINAL

(a) Check that the battery terminals are not loose or corroded.

If a terminal is loose or corroded, tighten or clean the terminal.

Torque:

Positive (+) Battery Terminal :

5.0 N·m {51 kgf·cm, 44 in·lbf}

Negative (-) Battery Terminal :

5.4 N·m {55 kgf·cm, 48 in·lbf}

3. CHECK FUSES

(a) Measure the resistance of each fuse for the charging system.

HINT:

The fuses shown in System Diagram are related to the charging system.

Standard resistance:

Below 1 Ω

  • If the result is not as specified, replace the fuse.

4. INSPECT V-RIBBED BELT

Click here 2021 - 2024 MY RAV4 [08/2020 -        ]; A25A-FKS (ENGINE MECHANICAL): ENGINE: ON-VEHICLE INSPECTION+

5. INSPECT GENERATOR ASSEMBLY WIRING

(a) Visually check the generator assembly wiring.

(1) Check that the wiring is in good condition.

6. CHECK FOR ABNORMAL NOISE

(a) Check for abnormal noises from the generator assembly.

(1) Check that no abnormal noises are heard from the generator assembly while the engine is running.

If noise occurs, refer to Problem Symptoms Table.

Click here 2019 - 2024 MY RAV4 [11/2018 -        ]; A25A-FKS (BATTERY / CHARGING): CHARGING SYSTEM: PROBLEM SYMPTOMS TABLE

7. INSPECT CHARGING CIRCUIT WITHOUT LOAD

CAUTION:

  • To prevent injury due to contact with an operating V-ribbed belt or cooling fan, keep your hands and clothing away from the V-ribbed belt and cooling fans when working in the engine compartment with the engine running or the ignition switch ON.
  • To prevent burns, do not touch the engine, exhaust manifold or other high temperature components while the engine is hot.

(a) Connect a voltmeter and an ammeter to the charging circuit as follows.

HINT:

If a battery/generator assembly tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.

(1) Disconnect the wire from terminal B of the generator assembly and connect it to the negative (-) lead of the ammeter.

(2) Connect the ammeter positive (+) lead to terminal B of the generator assembly.

(3) Connect the voltmeter positive (+) lead to the positive (+) terminal of the battery.

(4) Ground the voltmeter negative (-) lead.

*1

Generator Assembly

*2

Battery

*a

Terminal B

(b) Check the charging circuit.

(1) Maintain the engine speed at 2000 rpm and check the readings on the ammeter and voltmeter.

Standard current:

10 A or higher

Standard voltage:

12.5 to 14.8 V

If the result is not as specified, repair or replace the generator assembly.

8. INSPECT CHARGING CIRCUIT WITH LOAD

CAUTION:

  • To prevent injury due to contact with an operating V-ribbed belt or cooling fan, keep your hands and clothing away from the V-ribbed belt and cooling fans when working in the engine compartment with the engine running or the ignition switch ON.
  • To prevent burns, do not touch the engine, exhaust manifold or other high temperature components while the engine is hot.

(a) With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.

(b) Check the reading on the ammeter.

Standard current:

30 A or higher

If the result is not as specified, repair or replace the generator assembly.

HINT: