Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026TKL |
Model Year Start: 2023 |
Model: RAV4 HV |
Prod Date Range: [10/2022 - 10/2023] |
Title: A25A-FXS (COOLING): FLOW SHUTTING VALVE: REMOVAL; 2023 MY RAV4 HV [10/2022 - 10/2023] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water by-pass hose assembly) removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedures
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Auxiliary battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane control system
|
|
Parking support brake system*
|
Pre-collision system
|
Reset back door close position
|
Power back door system
|
|
Back door lock initialization
|
Power door lock control system
|
|
Replacement of inverter with converter assembly
|
Resolver learning
|
-
DTCs are stored
-
Slight vibration at a vehicle speed of 5 km/h (3 mph) or less
-
Shock or vibration during acceleration
|
for AWD with NICKEL METAL HYDRIDE BATTERY:
for LITHIUM-ION BATTERY:
|
Replacement of ECM
|
Perform Vehicle Identification Number (VIN) registration
|
DTC P063051 is output
|
|
Grille shutter switch specification infomation
|
Vehicle control history (RoB) [X260E] is stored
|
|
NOTICE:
-
After the ignition switch is turned off, the audio and visual system records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 2 minutes before disconnecting the cable from the negative (-) auxiliary battery terminal.
-
When the cable is disconnected from the negative (-) auxiliary battery terminal and the security lock setting has been enabled, multi-display operations will be disabled upon next startup unless the password is entered. Be sure to check the security lock setting before disconnecting the cable from the negative (-) auxiliary battery terminal.
PROCEDURE
1. REMOVE INVERTER WITH CONVERTER ASSEMBLY
Click here
2. DRAIN ENGINE COOLANT (for Engine)
Click here
3. REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
(a) Disconnect the flow shutting valve (water by-pass hose assembly) connector.
|
|
(b) Disconnect the outlet heater water hose connector from the No. 2 water by-pass pipe sub-assembly.
NOTICE:
Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater water hose connector before performing this work.
(1) Pull out the retainer to detach the lock claws and pull off the outlet heater water hose connector.
*a
|
Retainer
|
|
Pull out
|
|
Pull off
|
(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
(3) Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater water hose connector with plastic bags to prevent damage and contamination.
(c) Disconnect the inlet heater water hose connector from the flow shutting valve (water by-pass hose assembly).
NOTICE:
Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater water hose connector before performing this work.
(1) Pull out the retainer to detach the lock claws and pull off the inlet heater water hose connector.
*a
|
Retainer
|
|
Pull out
|
|
Pull off
|
(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
(3) Cover the disconnected inlet heater water hose connector with a plastic bag to prevent damage and contamination.
(d) Remove the bolt to disconnect the No. 2 water by-pass pipe sub-assembly.
|
|
(e) Remove the bolt to disconnect the flow shutting valve (water by-pass hose assembly).
|
|
(f) Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the water by-pass outlet sub-assembly.
HINT:
Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and water by-pass outlet sub-assembly.
|
|
|