Vehicle Speed
|
Vehicle speed
|
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
|
Target Engine Power
|
Target engine power
|
Min.: 0 W, Max.: 655350 W
|
Execute Engine Power
|
Execute engine power
|
Min.: 0 W, Max.: 655350 W
|
Target Engine Revolution
|
Target engine revolution
|
Min.: 0 rpm, Max.: 32767 rpm
|
Engine Speed
|
Engine speed
|
-
|
Calculate Load
|
Calculate load
|
Min.: 0.00%, Max.: 100.00%
|
Coolant Temperature
|
Engine coolant temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Starter Switch Signal
|
Starter ON / OFF signal
|
ON or OFF
|
Engine Idling Request
|
Engine idling request
|
ON or OFF
|
Engine Start Request (A/C)
|
Engine idling request from air conditioning amplifier assembly
|
ON or OFF
|
Engine Start Request (Engine Warm-up)
|
Engine idling request to warm up engine
|
ON or OFF
|
Engine Start Request (Hybrid/EV Battery Charging)
|
Engine idling request to charge HV battery
|
ON or OFF
|
Engine Mode
|
Engine status
|
Stop / Stop Process / Startup Process / Running
|
Engine Run Time
|
Elapsed time after starting engine
|
Min.: 0 sec, Max.: 65535 sec
|
Engine Stop Request
|
Engine stop request
|
ON or OFF
|
Engine Stop F/C Status
|
Engine fuel cut status
|
ON or OFF
|
Lack of Fuel
|
Lack of fuel
|
ON or OFF
|
Accelerator Position
|
Accelerator pedal depressed angle
|
Min.: 0.0%, Max.: 100.0%
|
Accelerator Pedal Status
|
Accelerator pedal status
|
ON or OFF
|
Accelerator Position Sensor No.1 Voltage %
|
Accelerator pedal position sensor No. 1
|
Min.: 0.00%, Max.: 100.00%
|
Accelerator Position Sensor No.2 Voltage %
|
Accelerator pedal position sensor No. 2
|
Min.: 0.00%, Max.: 100.00%
|
Throttle Position Sensor No.1 Voltage %
|
Throttle valve angle
|
Min.: 0.00%, Max.: 100.00%
|
Master Cylinder Control Torque
|
Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque)
|
-
|
Brake Cancel Switch
|
Brake pedal status
|
ON or OFF
|
Shift Position
|
Current shift state
|
P / R / N / D / B
|
Shift Position (Meter)
|
Shift position of meter display
|
Not Displayed / P / R / N / D / B
|
Shift Switch Status (N,P Position)
|
Shift position status (N or P position)
|
ON or OFF
|
Shift Position Sensor (PNB)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (PR)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (DB1)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (DB2)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (N)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (R)
|
Shift position sensor
|
ON or OFF
|
Shift Position Sensor (P)
|
Shift position sensor
|
ON or OFF
|
Shift Lock Release Request
|
Shift lock release request
|
ON or OFF
|
Sports Shift Position
|
Sports shift position
|
Min.: 0, Max.: 255
|
Sports Shift UP Signal
|
Sports shift UP signal
|
ON or OFF
|
Sports Shift DOWN Signal
|
Sports Shift DOWN Signal
|
ON or OFF
|
Transaxle Oil Temperature
|
Hybrid vehicle transaxle oil temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Transaxle Oil Temperature Sensor Voltage
|
Hybrid vehicle transaxle oil temperature sensor voltage
|
Min: 0.00 V, Max: 4.99 V
|
FR Wheel Speed
|
Front wheel speed RH
|
Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
FL Wheel Speed
|
Front wheel speed LH
|
Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
RR Wheel Speed
|
Rear wheel speed RH
|
Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
RL Wheel Speed
|
Rear wheel speed LH
|
Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
Steering Angle
|
Steering angle value
(counterclockwise is positive)
|
-
|
Forward and Rearward G
|
Forward and rearward G value
|
-13.107 to 13.106 m/s2
|
Lateral G
|
Lateral G value
|
-13.107 to 13.106 m/s2
|
Yaw Rate Value
|
Yaw rate value
|
-128.0 to 127.9 deg/s
|
Atmospheric Pressure
|
Atmospheric pressure
|
Min.: 0 kPa, Max.: 255 kPa
|
Intake Manifold Absolute Pressure
|
Intake manifold pressure of engine
|
Min.: 0.00 kPa, Max.: 255.00 kPa
|
Ambient Temperature
|
Ambient air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Intake Air Temperature
|
Engine intake air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
BATT Voltage
|
Auxiliary battery voltage
(Battery voltage sensor power source voltage)
|
Min.: 0.00 V, Max.: 16.00 V
|
Smoothed Value of BATT Voltage
|
Smoothed value of auxiliary battery voltage
|
Min.: 0.000 V, Max.: 16.000 V
|
Warmup Cycle Cleared DTC
|
The number of times the engine is warmed up after clearing DTCs
|
Min.: 0, Max.: 255
|
Distance from DTC Cleared
|
Drive distance after clearing DTCs
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
Time after DTC Cleared
|
Elapsed time after clearing DTCs
|
Min.: 0 min, Max.: 65535 min
|
Running Time from MIL ON
|
Running time from MIL on
|
Min.: 0 min, Max.: 65535 min
|
Total Distance Traveled
|
Drive total distance
|
Min.: 0, Max.: 16777215
|
Total Distance Traveled - Unit
|
Drive total distance unit
|
km or mile
|
MIL ON Run Distance
|
Drive distance from MIL on
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
IGB Signal Status
|
IGB signal status
|
ON or OFF
|
IG2 Signal Status
|
IG2 signal status
|
ON or OFF
|
Ready Signal
|
Ready signal status
|
ON or OFF
|
HV/EV Activate Condition
|
Hybrid vehicle control system power source mode status
|
Normal / Remote Air Control System / Remote
|
MG Activate Condition
|
Motor generator control system status
|
ON or OFF
|
Request Torque for Rear Side
|
Requested rear motor (MGR) torque
|
Min.: -32768 Nm, Max.: 32767 Nm
|
DSS Control Status
|
Control status of DSS (Driving Support System)
|
Not Control / Available / Unavailable / Disable
|
Generate Torque (Request from DSS)
|
Generated drive torque requested from DSS (Driving Support System)
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Primary Driving Force Adjustment Result
|
Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation
|
Accelerator / DSS
|
SMRG Status
|
Operating state of SMRG
(primary circuit monitor)
|
ON or OFF
|
SMRG Control Status
|
Commanded state of SMRG
|
ON or OFF
|
SMRB Status
|
Operating state of SMRB
(primary circuit monitor)
|
ON or OFF
|
SMRB Control Status
|
Commanded state of SMRB
|
ON or OFF
|
SMRP Status
|
Operating state of SMRP
(primary circuit monitor)
|
ON or OFF
|
SMRP Control Status
|
Commanded state of SMRP
|
ON or OFF
|
WIN Control Limit Power
|
Charge control wattage sent from battery voltage sensor to hybrid vehicle control ECU assembly
|
Min.: -327.68 kW, Max.: 327.67 kW
|
WOUT Control Limit Power
|
Discharge control wattage sent from battery voltage sensor to hybrid vehicle control ECU assembly
|
Min.: -327.68 kW, Max.: 327.67 kW
|
Voltage Deviation between before Boosting and after Boosting during SMR Precharge
|
Difference in voltage before boosting and after boosting during system main relay precharge
|
Min.: -3276.8 V, Max.: 3276.7 V
|
A/C Consumption Power
|
A/C consumption power
|
Min.: 0.00 kW, Max.: 12.75 kW
|
EV Mode
|
EV mode transition availability
|
ON or OFF
|
EV Mode Switch
|
EV mode switch (integration control and panel assembly) condition
|
ON or OFF
|
Sport Mode Switch
|
SPORT mode switch (integration control and panel assembly) condition
|
ON or OFF
|
M/S/B Shift Position Signal
|
Shift position sensor
|
ON or OFF
|
Normal Mode Switch
|
NORMAL mode switch (integration control and panel assembly) condition
|
ON or OFF
|
Inter Lock Switch
|
Interlock switch condition
|
ON or OFF
|
Inter Lock Switch (MG)
|
Interlock switch condition
|
ON or OFF
|
Stop Light Switch
|
Stop light switch assembly condition
|
ON or OFF
|
Back Up Light Relay
|
Back up light switch condition
|
ON or OFF
|
VSC/TRC OFF Switch
|
VSC condition
|
OFF / TRC OFF Mode / TRC/VSC OFF Mode
|
Auto LSD Switch
|
TRAIL mode switch (integration control and panel assembly) condition
|
ON or OFF
|
Airbag Status (Collision) (CAN)
|
Airbag sensor assembly collision detection
(CAN)
|
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side
|
Crank Position
|
Crankshaft position
|
Min.: -128 deg (CA), Max.: 127 deg (CA)
|
TC Terminal
|
TC terminal state
|
ON or OFF
|
Generator Revolution
|
Generator (MG1) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
Target Generator Torque
|
Generator (MG1) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Generator Torque
|
Generator (MG1) torque execution value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Motor Revolution
|
Motor (MG2) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
Target Motor Torque
|
Motor (MG2) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Motor Torque
|
Motor (MG2) torque execution value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Rear Motor Revolution
|
Rear motor (MGR) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
Target Rear Motor Torque
|
Rear motor (MGR) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Rear Motor Torque
|
Rear motor (MGR) torque value
|
Min.: -4096.000 Nm, Max.: 4095.875 Nm
|
Rear Motor Torque Ratio
|
Rear motor torque ratio
|
-
|
Request Motor Regenerative Brake Torque
|
Requested motor (MG2) regenerative braking torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Motor Regenerate Brake Execution Torque
|
Motor (MG2) regenerative braking execution torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Request Rear Motor Regenerative Brake Torque
|
Requested rear motor (MGR) regenerative braking torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Rear Motor Regenerate Brake Execution Torque
|
Rear motor (MGR) regenerative braking execution torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Generator Temperature
|
Generator (MG1) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Generator Temperature Sensor Voltage
|
Generator (MG1) temperature sensor voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
Generator Temperature just after IG ON
|
Generator (MG1) temperature soon after ignition switch ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Generator Maximum Temperature
|
Maximum generator (MG1) temperature after ignition switch turned ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Motor Temperature
|
Motor (MG2) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Motor Temperature Sensor Voltage
|
Motor (MG2) temperature sensor voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
Motor Temperature just after IG ON
|
Motor (MG2) temperature soon after ignition switch ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Motor Maximum Temperature
|
Maximum motor (MG2) temperature after ignition switch turned ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Rear Motor Temperature
|
Rear motor (MGR) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Rear Motor Temperature Sensor Voltage
|
Rear motor (MGR) temperature sensor voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
Rear Motor Temperature just after IG ON
|
Rear motor (MGR) temperature soon after ignition switch ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Rear Motor Maximum Temperature
|
Maximum rear motor (MGR) temperature after ignition switch turned ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Generator Inverter Temperature
|
Generator inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Generator Inverter Temperature just after IG ON
|
Generator inverter temperature soon after ignition switch ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Generator Inverter Maximum Temperature
|
Maximum generator inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Motor Inverter Temperature
|
Motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Motor Inverter Temperature just after IG ON
|
Motor inverter temperature soon after ignition switch ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Motor Inverter Maximum Temperature
|
Maximum motor inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Rear Motor Inverter Temperature
|
Rear motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Rear Motor Inverter Temperature just after IG ON
|
Rear motor inverter temperature soon after ignition switch ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Rear Motor Inverter Temperature before Operation
|
Temperature of rear motor inverter before operation
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Rear Motor Inverter Maximum Temperature
|
Maximum rear motor inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Boosting Converter Temperature (Upper)
|
Boost converter temperature (upper)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Boosting Converter Temperature (Lower)
|
Boost converter temperature (lower)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Boosting Converter Temperature just after IG ON
|
Boost converter temperature soon after ignition switch ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Boosting Converter Maximum Temperature
|
Maximum converter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Generator Inverter Operation Request
|
Generator inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
Generator Inverter Fail
|
Generator inverter stopped
|
ON or OFF
|
Generator Inverter Shutdown Status
|
Generator inverter shutdown status
|
Awake or Shutdown
|
Motor Inverter Operation Request
|
Motor inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
Motor Inverter Fail
|
Motor inverter stopped
|
ON or OFF
|
Motor Inverter Shutdown Status
|
Motor inverter shutdown status
|
Awake or Shutdown
|
Rear Motor Inverter Operation Request
|
Rear motor inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
Rear Motor Inverter Fail
|
Rear motor inverter stopped
|
ON or OFF
|
Rear Motor Inverter Shutdown Status
|
Rear inverter shutdown status
|
ON or OFF
|
Boosting Converter Operation Request
|
Boosting converter operation request
|
Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering
|
Boosting Converter Fail
|
Boost converter stopped
|
ON or OFF
|
Boosting Converter Shutdown Status
|
Boost converter shutdown status
|
Awake or Shutdown
|
Generator Carrier Frequency
|
Generator carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
Generator Control Mode
|
Generator (MG1) control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
Motor Carrier Frequency
|
Motor (MG2) carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
Motor Control Mode
|
Motor (MG2) control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
Rear Motor Carrier Frequency
|
Rear Motor carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
Rear Motor Control Mode
|
Rear Motor control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
Boosting Converter Carrier Frequency
|
Boost converter signal carrier frequency
|
9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz
|
VL-Voltage before Boosting
|
High voltage before it is boosted
|
-
|
VL-Voltage before Boosting for Rear Motor
|
Rear motor supply voltage before it is boosted
|
-
|
VH-Voltage after Boosting
|
High voltage after it is boosted
|
-
|
Boost Ratio
|
Boost converter boost ratio
|
Min.: 0.0%, Max.: 100.0%
|
V Phase Generator Current
|
V phase generator current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
W Phase Generator Current
|
W phase generator current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
V Phase Motor Current
|
V phase motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
W Phase Motor Current
|
W phase motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
V Phase Rear Motor Current
|
V phase rear motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
W Phase Rear Motor Current
|
W phase rear motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Inverter Coolant Water Temperature
|
Inverter coolant temperature
|
Min.: -40°C (-40°F), Max.: 110°C (230°F)
|
Inverter Water Pump Duty Ratio
|
Inverter water pump motor driver request duty
|
Min.: 0.0%, Max.: 100.0%
|
Inverter Water Pump Revolution
|
Inverter water pump assembly speed
|
Min.: 0 rpm, Max.: 15000 rpm
|
Overvoltage Input to Inverter
|
Overvoltage detection into inverter
|
ON or OFF
|
Inverter Emergency Shutdown (Main CPU)
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter Emergency Shutdown (Sub CPU)
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter Input Current
|
Inverter input current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Overvoltage Input to Boosting Converter
|
Overvoltage detection into boost converter
|
ON or OFF
|
Motor/Generator Reactor Current before SMR Precharge
|
Reactor current before system main relay precharge
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Motor/Generator Reactor Maximum Current during SMR Precharge
|
Highest reactor current during system main relay precharge
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Motor/Generator Reactor Current-Carrying Status during SMR Precharge
|
Current flowing through reactor during system main relay precharge
|
Indefinite / Definite
|
Motor/Generator Reactor Noncurrent-Carrying Status during SMR Precharge
|
Current not flowing through reactor during system main relay precharge
|
Indefinite / Definite
|
Hybrid/EV Battery SOC
|
HV battery state of charge
Primary calculated from charging and discharging amperage
|
Min.: 0.00%, Max.: 100.00%
|
Delta SOC
|
Difference between maximum and minimum values of SOC
|
Min.: 0.0%, Max.: 100.0%
|
Hybrid/EV Battery SOC of Immediately after IG ON
|
HV battery state of charge soon after ignition switch ON
|
Min.: 0.0%, Max.: 100.0%
|
Hybrid/EV Battery Maximum SOC
|
Maximum SOC after ignition switch turned ON in current trip
|
Min.: 0.0%, Max.: 100.0%
|
Hybrid/EV Battery Minimum SOC
|
Minimum SOC after ignition switch turned ON in current trip
|
Min.: 0.0%, Max.: 100.0%
|
Hybrid/EV Battery Voltage
|
HV battery voltage
|
Min.: 0.00 V, Max.: 1023.98 V
|
Hybrid/EV Battery Current
|
HV battery current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Hybrid/EV Battery Current for Hybrid/EV Battery Control
|
Hybrid battery current for hybrid battery control
|
Min.: -327.68 A, Max.: 327.67 A
|
Hybrid/EV Battery Current for Driving Control
|
Hybrid battery current for driving control
|
Min.: -327.68 A, Max.: 327.67 A
|
Hybrid/EV Battery Control Mode
|
HV battery control mode
|
Driving Control Mode / Current Sensor Offset Calibration Mode / Hybrid Battery External Charging Control Mode / ECU Shutdown Mode
|
Hybrid/EV Battery Block 1 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 2 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 3 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 4 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 5 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 6 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 7 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 8 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 9 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 10 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Block 11 Voltage
|
Battery block voltage
|
Min.: 0.00 V, Max.: 79.99 V
|
Hybrid/EV Battery Temperature 1
|
Battery module temperature
|
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
|
Hybrid/EV Battery Temperature 2
|
Battery module temperature
|
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
|
Hybrid/EV Battery Temperature 3
|
Battery module temperature
|
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
|
Hybrid/EV Battery Cooling Fan 1 Drive Request
|
Hybrid battery cooling blower operation request
|
Min.: 0.0%, Max.: 100.0%
|
Hybrid/EV Battery Cooling Fan 1 Drive Status
|
Battery cooling blower assembly operation mode
|
0 / 1 / 2 / 3 / 4 / 5 / 6 / 10 / 20 / 30
|
Hybrid/EV Battery Cooling Fan 1 Frequency
|
Battery cooling blower assembly frequency
|
Min.: 0.0 Hz, Max.: 6553.5 Hz
|
Hybrid/EV Battery Cooling Fan Intake Air Temperature 1
|
Hybrid battery intake air temperature
|
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
|
Hybrid/EV Battery Cooling Fan Low Speed Request
|
Battery cooling blower assembly Lo speed requested
|
ON or OFF
|
Hybrid/EV Battery Sensor Module Power Supply Voltage
|
Battery voltage sensor power supply voltage
|
Min.: 0.00 V, Max.: 16.00 V
|
Hybrid/EV Battery Monitoring IC 1 Voltage 1
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Monitoring IC 1 Voltage 2
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Monitoring IC 2 Voltage 1
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Monitoring IC 2 Voltage 2
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Monitoring IC 3 Voltage 1
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Monitoring IC 3 Voltage 2
|
Hybrid battery monitoring circuit voltage
|
Min.: -327.68 V, Max.: 327.67 V
|
Hybrid/EV Battery Current Sensor Power Supply Voltage
|
Hybrid battery current sensor power supply voltage
|
Min.: 0.0 V, Max.: 25.5 V
|
Hybrid/EV Battery Current Sensor Offset Learning Value
|
Hybrid battery current sensor offset learning value
|
Min.: -327.68 A, Max.: 327.67 A
|
Hybrid/EV Battery Current Sensor Offset (High)
|
Hybrid battery current sensor offset (High)
|
Min.: -327.68 A, Max.: 327.67 A
|
Number of Hybrid/EV Battery Current Sensor Characteristics Determination
|
Number of times battery current sensor characteristic judgment is performed
|
Min.: 0, Max.: 255
|
Short Wave Highest Value Level
|
Waveform voltage level in abnormal insulation detection circuit in battery voltage sensor
|
Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3
|
Insulation Resistance Division Check Completion using Rear Motor Inv
|
Insulation resistance division check completion using rear motor inverter
|
Not Complete / Complete
|
Insulation Resistance Division Check Completion using MG Inv
|
Insulation resistance division check completion using MG inverter
|
Not Complete / Complete
|
Insulation Resistance Division Check Completion using A/C Inv
|
Insulation resistance division check completion using A/C inverter
|
Not Complete / Complete
|
Insulation Resistance Division Check Completion using SMR
|
Insulation resistance division check completion using SMR
|
Not Complete / Complete
|
Short Wave Highest Value Availability just after Rear Motor Inv On/Off
|
Short wave highest value availability just after rear motor inverter on/off
|
No or Yes
|
Short Wave Highest Value Availability just after MG Inv On/Off
|
Short wave highest value availability just after MG inverter on/off
|
No or Yes
|
Short Wave Highest Value Availability just after A/C Inv On/Off
|
Short wave highest value availability just after A/C inverter on/off
|
No or Yes
|
Short Wave Highest Value Availability just after SMR On/Off
|
Short wave highest value availability just after SMR on/off
|
No or Yes
|
Immobiliser Communication
|
Immobiliser communication line status
|
ON or OFF
|
Permit Start by Immobiliser
|
Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU assembly)
|
No Judgment / OK / NG
|
Auxiliary Battery Voltage
|
Auxiliary battery voltage
|
Min.: 0.00 V, Max.: 16.00 V
|
Auxiliary Battery Voltage just before SMR Precharge
|
Auxiliary battery voltage just before SMR precharge
|
Min.: 0.00 V, Max.: 79.99 V
|
Auxiliary Battery Current
|
Auxiliary battery current
|
Min.: -125.00 A, Max.: 124.99 A
|
Smoothed Value of Auxiliary Battery Temperature
|
Smoothed value of auxiliary battery temperature
|
Min.: -30.0°C (-22.0°F), Max.: 6513.5°C (11756.3°F)
|
Auxiliary Battery Status of Full Charge
|
Auxiliary battery status when full charge
|
Min.: 0.0 Ah, Max.: 127.5 Ah
|
Auxiliary Battery Charging Rate Accuracy
|
Auxiliary battery charging rate accuracy
|
Low / Middle / High / Disable
|
Auxiliary Battery Dark Current
|
Auxiliary battery dark current
|
Min.: 0 mA, Max.: 65535 mA
|
Auxiliary Battery Sensor Sleep Time
|
Auxiliary battery sensor sleep time
|
Min.: 0 h, Max.: 255 h
|
Power Feeding Electrical Using Status
|
Usage state of power supplied from external power source charging
|
Charge Sustaining Mode/Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF
|