Last Modified: 06-02-2026 |
6.11:8.1.0 |
Doc ID: RM100000001QM72 |
|
Model Year Start: 2021 |
Model: RAV4 HV |
Prod Date Range: [08/2020 -
] |
|
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): UTILITY; 2021 - 2025 MY RAV4 HV [08/2020 - ] |
UTILITY
1. REFRIGERANT HIGH PRESSURE HISTORY CLEAR
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant High Pressure History Clear.
Body Electrical > Air Conditioner > Utility
2. REFRIGERANT SHORTAGE CHECK USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
|
Item
|
Condition
|
|
Vehicle Condition
|
Ignition switch ON (READY)
|
|
A/C Switch
|
On
|
|
Ambient Temperature*1
|
0 to 49°C (32 to 120°F)
|
|
Air Conditioning Air Inlet Temperature*2
|
25 to 35°C (77 to 95°F)
|
|
Set Temperature
|
MAX COLD
|
|
Recirculation/fresh Control Switch
|
Recirculation
|
|
Air Vent Damper Position
|
FACE
|
|
Blower Speed
|
HI
|
HINT:
-
Refer to the Techstream operator's manual for further details.
-
A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
-
DTCs are not stored when performing the refrigerant shortage check using the Techstream.
-
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
-
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
Result:
|
Result
|
Amount of Refrigerant
|
Corrective Action
|
|
Refrigerant shortage
|
Insufficient
|
-
Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
-
Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
|
|
Refrigerant correct
|
Correct
|
-
|
|
Refrigerant incorrect
|
Incorrect
|
Confirm check condition and carry out again
|
|