Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001QEWT |
Model Year Start: 2021 |
Model: RAV4 |
Prod Date Range: [08/2020 - 12/2021] |
Title: A25A-FXS (ENGINE CONTROL): SFI SYSTEM: P043E00,P043F00,P24007E,P24007F,P24187E; Evaporative Emission System Leak Detection Reference Orifice Low Flow; 2021 MY RAV4 RAV4 HV [08/2020 - 12/2021] |
DTC
|
P043E00
|
Evaporative Emission System Leak Detection Reference Orifice Low Flow
|
DTC
|
P043F00
|
Evaporative Emission System Leak Detection Reference Orifice High Flow
|
DTC
|
P24007E
|
Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck On
|
DTC
|
P24007F
|
Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck Off
|
DTC
|
P24187E
|
Evaporative Emission System Switching Valve Control Circuit Actuator Stuck On
|
DTC SUMMARY
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P043E00
|
Evaporative Emission System Leak Detection Reference Orifice Low Flow
|
Reference orifice detected as clogged during key-off EVAP monitor.
|
-
Canister pump module
-
Connector/wire harness (Canister pump module - ECM)
-
EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P043E
-
DTC for Mexico Models: Does not apply
|
P043F00
|
Evaporative Emission System Leak Detection Reference Orifice High Flow
|
Reference orifice flow high during key-off EVAP monitor.
|
-
Canister pump module
-
Connector/wire harness (Canister pump module - ECM)
-
EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P043F
-
DTC for Mexico Models: Does not apply
|
P24007E
|
Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck On
|
Leak detection pump on malfunction detected during key-off EVAP monitor.
|
-
Canister pump module
-
Connector/wire harness (Canister pump module - ECM)
-
EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P2402
-
DTC for Mexico Models: Does not apply
|
P24007F
|
Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck Off
|
Leak detection pump off malfunction detected during key-off EVAP monitor.
|
-
Canister pump module
-
Connector/wire harness (Canister pump module - ECM)
-
EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P2401
-
DTC for Mexico Models: Does not apply
|
P24187E
|
Evaporative Emission System Switching Valve Control Circuit Actuator Stuck On
|
Vent valve on (closed) malfunction detected during key-off EVAP monitor.
|
-
Canister pump module
-
Connector/wire harness (Canister pump module - ECM)
-
EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P2419
-
DTC for Mexico Models: Does not apply
|
HINT:
The reference orifice is located inside the canister pump module.
DTC No.
|
Monitoring Item
|
Detection Timing
|
Detection Logic
|
SAE Code
|
P043E00
|
Reference orifice clogged
|
EVAP monitoring
(Ignition switch off)
|
2 trip
|
P043E
|
P043F00
|
Reference orifice high-flow
|
P043F
|
P24007E
|
Leak detection pump stuck ON
|
P2402
|
P24007F
|
Leak detection pump stuck OFF
|
P2401
|
P24187E
|
Vent valve stuck closed
|
P2419
|
DESCRIPTION
Refer to EVAP (Evaporative Emission) System.
Click here
MONITOR DESCRIPTION
In sequence B and E, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM, using the canister pressure sensor, to determine the reference pressure. If the pressure detected meets one of the following conditions, the ECM will illuminated the MIL and store a DTC (2 trip detection logic).
-
EVAP pressure is lower than the malfunction criterion.
-
EVAP pressure is higher than the malfunction criterion.
-
EVAP pressure is not saturated within 60 seconds.
-
EVAP pressure difference between sequence B and E is large.
MONITOR STRATEGY
Required Sensors/Components (Main)
|
Canister pump module
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Once per driving cycle
|
Duration
|
Within 7 minutes
|
MIL Operation
|
2 driving cycles
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
Key-off monitor runs when all of the following conditions are met
|
-
|
Atmospheric pressure
|
70 kPa(abs) [10.2 psi(abs)] or higher, and less than 110 kPa(abs) [16 psi(abs)]
|
Auxiliary battery voltage
|
10.5 V or higher
|
Vehicle speed
|
Less than 4 km/h (2.5 mph)
|
Ignition switch
|
Off
|
Engine condition
|
Not running
|
Key-OFF duration
|
5, 7 or 9.5 hours
|
Pressure sensor of canister pump module malfunction (P0452 and P0453)
|
Not detected
|
Fuel tank pressure sensor malfunction (P1452 and P1453)
|
Not detected
|
Purge VSV
|
Not operated by scan tool
|
Vent valve
|
Not operated by scan tool
|
Fuel vapor-containment valve
|
Not operated by scan tool
|
Leak detection pump
|
Not operated by scan tool
|
Purge flow before key-OFF
|
Performed
|
Engine coolant temperature
|
4.4°C (39.9°F) or higher, and less than 35°C (95°F)
|
Intake air temperature
|
4.4°C (39.9°F) or higher, and less than 35°C (95°F)
|
TYPICAL MALFUNCTION THRESHOLDS
One of following conditions met
|
-
|
EVAP pressure when 1.9 seconds after reference pressure measurement began
|
Higher than -0.242 kPa(gauge) [-0.0351 psi(gauge)]
|
Reference pressure (vary with atmospheric pressure)
|
Less than -4.85 kPa(gauge) [-0.7 psi(gauge)]
|
Reference pressure (vary with atmospheric pressure)
|
-1.068 kPa(gauge) [-0.155 psi(gauge)] or higher
|
Reference pressure (vary with atmospheric pressure)
|
Not saturated
|
Reference pressure difference between the first and second
|
0.9 kPa(gauge) [0.1 psi(gauge)] or higher
|
MONITOR RESULT
Refer to EVAP System.
Click here
CONFIRMATION DRIVING PATTERN
NOTICE:
-
The Evaporative System Check (Automatic Mode) consists of 9 steps performed automatically by the Techstream. It takes a maximum of approximately 40 minutes.
-
Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
-
Do not start the engine during this operation.
-
When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor will from and any check result will be inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON.
-
Turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON [A].
-
Turn the Techstream on.
-
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode [B].
-
After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine / Utility / All Readiness.
-
Input the DTC: P043E00, P043F00, P24007E, P24007F or P24187E.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
CAUTION / NOTICE / HINT
NOTICE:
-
Vehicle Control History may be stored in the hybrid vehicle control ECU assembly if the engine is malfunctioning. Certain vehicle condition information is recorded when Vehicle Control History is stored. Reading the vehicle conditions recorded in both the freeze frame data and Vehicle Control History can be useful for troubleshooting.
for AWD with NICKEL METAL HYDRIDE BATTERY
Click here
for LITHIUM-ION BATTERY
Click here
(Select Powertrain in Health Check and then check the time stamp data.)
Click here
-
If any "Engine Malfunction" Vehicle Control History item has been stored in the hybrid vehicle control ECU assembly, make sure to clear it. However, as all Vehicle Control History items are cleared simultaneously, if any Vehicle Control History items other than "Engine Malfunction" are stored, make sure to perform any troubleshooting for them before clearing Vehicle Control History.
for AWD with NICKEL METAL HYDRIDE BATTERY
Click here
for LITHIUM-ION BATTERY
Click here
PROCEDURE
(a) Refer to EVAP System.
Click here
NEXT |
|
END
|
|