Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FPHV |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 02/2019] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): Recirculated/Fresh Air Modes Switch without User Input; 2019 MY RAV4 HV [11/2018 - 02/2019] |
Recirculated/Fresh Air Modes Switch without User Input
|
DESCRIPTION
If fresh/recirculation mode changes unintentionally and without permission, the following causes are possible.
Malfunction Status
|
Factor
|
-
Fresh/recirculation mode changes without permission
-
Fresh/recirculation mode light blinks
|
-
Automatic function set to ON in the customize setting
-
Change in fresh air temperature
-
Refrigerant pressure drop
-
Pressure sensor circuit
-
High engine coolant temperature
|
PROCEDURE
1.
|
CHECK CUSTOMIZE SETTING
|
(a) Use the following customize setting methods to check if the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
Click here
-
Check setting using Techstream
-
Check setting by multi-display
OK:
Customize setting is "OFF".
NG |
|
CHANGE CUSTOMIZE SETTING IS ON
|
OK
|
|
|
2.
|
READ VALUE USING TECHSTREAM (AMBIENT TEMP SENSOR)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Ambient Temp Sensor
|
Thermistor assembly
|
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Thermistor assembly system malfunction
-
When open circuit: -23.30°C (-9.94°F)
-
When short circuit: 65.95°C (150.71°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Ambient Temp Sensor
|
OK:
The value of the display does not change frequently.
OK
|
|
|
3.
|
READ VALUE USING TECHSTREAM (COOLANT TEMPERATURE)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / Engine / Data List.
(e) Read the Data List according to the display on the Techstream.
Powertrain > Engine > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Coolant Temperature
|
Engine coolant temperature
|
Min.: -40°C (-40°F), Max.: 140°C (284°F)
|
75 to 100°C (167 to 212°F): After warming up
|
This is the engine coolant temperature.
HINT:
-
After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
-
After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
-
If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
-
Check if the engine overheats if the value indicated is higher than 135°C (275°F).
|
Powertrain > Engine > Data List
Tester Display
|
Coolant Temperature
|
OK:
The value of the display does not change frequently.
OK
|
|
|
4.
|
CHECK REFRIGERANT PRESSURE
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.6 kPaG (gauge)
Max.: 3294.3 kPaG (gauge)
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor system malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
(f) Install a manifold gauge set.
-
for HFC-134a (R134a):
-
for HFO-1234yf (R1234yf):
(g) Read the manifold gauge pressure when the following conditions are met.
(1) Prepare the vehicle according to the table below.
Measurement Condition:
Item
|
Condition
|
Vehicle Condition
|
Power switch on (READY)
|
Doors
|
Fully closed (windows also fully closed)
|
A/C Switch
|
On
|
Recirculation/fresh Control Switch
|
Recirculation
|
Set Temperature
|
MAX COLD
|
Blower Speed
|
HI
|
Air Conditioning Air Inlet Temperature
|
25 to 35°C (77 to 95°F)
|
Standard Pressure:
Low pressure side
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High pressure side
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
(h) Compare the values displayed in the Data List and on the manifold gauge.
OK:
The values displayed in the Data List and on the manifold gauge match.
|