Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): Weak Blower Output; 2019 - 2025 MY RAV4 HV [11/2018 - ] |
DESCRIPTION
If the blower airflow volume is weak regardless of the integration control and panel assembly being normal, the following causes are possible.
|
Malfunction Status
|
Factor
|
-
Blower airflow volume is continuously weak
-
Blower airflow volume is sometimes weak
|
-
Communication malfunction between air conditioning amplifier assembly and blower with fan motor sub-assembly
-
Air conditioning amplifier assembly malfunction
-
Blower with fan motor sub-assembly malfunction
-
Clean air filter is clogging
-
Evaporator or heater core fin clogging
-
ECO drive mode function (air flow volume is restricted due to ECO drive mode being selected)
-
Aspirator dropped
|
PROCEDURE
|
1.
|
CHECK BLOWER FAN OPERATION
|
(a) Prepare the vehicle according to the table below in manual mode.
|
Blower Switch
|
Condition
|
|
LO → HI
|
-
Temperature setting: Max COLD
-
Mode switch: FACE
-
A/C switch: Off
|
OK:
Airflow volume is changed.
|
OK
|
|
|
|
2.
|
CHECK ECO DRIVE MODE OPERATION
|
(a) Confirm setup of the ECO drive mode and turn it off if it is on.
HINT:
-
When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.
|
Control
|
Control Summary
|
|
Airflow Control
|
Automatically switches the air inlet port to the internal air circulation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption.
|
|
Air Inlet Control
|
Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption.
|
-
If integration control and panel assembly (ECO switch) is malfunctioning, perform diagnosis on the ECO switch circuit.
Click here
|
NEXT
|
|
|
|
3.
|
CHECK CLEAN AIR FILTER
|
(a) Visually check the clean air filter.
OK:
The clean air filter is not dirty or clogging.
|
OK
|
|
|
|
4.
|
CHECK NO. 1 COOLER THERMISTOR
|
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
No. 1 cooler thermistor is installed correctly.
|
OK
|
|
|
(a) Check the installation condition of the aspirator.
OK:
Aspirator is installed correctly.
| OK |
|
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR (HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR WAS CLOGGING)
|
|