Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FPH0 |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 02/2019] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): B1413; Evaporator Temperature Circuit or Evaporator Fin Thermistor; 2019 MY RAV4 HV [11/2018 - 02/2019] |
DTC
|
B1413
|
Evaporator Temperature Circuit or Evaporator Fin Thermistor
|
DESCRIPTION
The No. 1 cooler thermistor is installed to the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B1413
|
Evaporator Temperature Sensor Circuit
|
-
Diagnosis condition: None
-
Malfunction status: Open or short in evaporator temperature sensor circuit
-
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
-
No. 1 cooler thermistor
-
Air conditioning harness assembly
-
Air conditioning amplifier assembly
|
Memorized
|
WIRING DIAGRAM
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM (EVAPORATOR FIN THERMISTOR)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Evaporator Fin Thermistor
|
No. 1 cooler thermistor
|
Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
|
Actual evaporator temperature displayed
|
No. 1 cooler thermistor system malfunction
-
When open circuit: -29.70°C (-21.46°F)
-
When short circuit: 59.55°C (139.19°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Evaporator Fin Thermistor
|
OK:
The display is as specified in the normal condition column.
NG
|
|
|
2.
|
INSPECT NO. 1 COOLER THERMISTOR
|
(a) Remove the No. 1 cooler thermistor.
Click here
(b) Inspect the No. 1 cooler thermistor.
Click here
OK
|
|
|
3.
|
INSPECT AIR CONDITIONING HARNESS ASSEMBLY
|
(a) Remove the air conditioning harness assembly.
Click here
*a
|
Front view of air conditioning harness assembly connector
(to Air Conditioning Amplifier Assembly)
|
*b
|
Front view of air conditioning harness assembly connector
(to No. 1 Cooler Thermistor)
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z11-6 (TEA) - 2
|
Always
|
Below 1 Ω
|
z11-5 (SGA) - 1
|
Always
|
Below 1 Ω
|
z11-6 (TEA) or 2 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
z11-5 (SGA) or 1 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
|