Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FOZ0 |
Model Year Start: 2019 |
Model: RAV4 |
Prod Date Range: [11/2018 -
] |
Title: THEFT DETERRENT / KEYLESS ENTRY: THEFT DETERRENT SYSTEM: Security Horn Circuit; 2019 - 2024 MY RAV4 RAV4 HV [11/2018 - ] |
DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
1.
|
PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY HORN)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Active Test.
(e) According to the display on the Techstream, perform the Active Test.
Body Electrical > Main Body > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Security Horn
|
Security horn assembly
|
ON or OFF
|
-
|
Body Electrical > Main Body > Active Test
Tester Display
|
Security Horn
|
OK:
The security horn assembly sounds and stops correctly when operated through the Techstream.
NG
|
|
|
2.
|
INSPECT SECURITY HORN ASSEMBLY
|
(a) Remove the security horn assembly.
Click here
(b) Inspect the security horn assembly.
Click here
OK
|
|
|
3.
|
INSPECT SECURITY WARNING RELAY (S-HORN)
|
(a) Remove the security warning relay (S-HORN).
|
|
(b) Measure the resistance according to the value(s) in the table below
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Security warning relay (S-HORN) terminal 3 - Security warning relay (S-HORN) terminal 5
|
Auxiliary battery voltage is applied between security warning relay (S-HORN) terminals 2 - 1
|
Below 1 Ω
|
Security warning relay (S-HORN) terminal 3 - Security warning relay (S-HORN) terminal 5
|
Auxiliary battery voltage is not applied between security warning relay (S-HORN) terminals 2 - 1
|
10 kΩ or higher
|
NG |
|
REPLACE SECURITY WARNING RELAY (S-HORN RELAY)
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (SECURITY WARNING RELAY [S-HORN] - MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU])
|
(a) Remove the main body ECU (multiplex network body ECU).
Click here
(b) Connect the instrument panel junction block assembly connectors.
(c) Remove the security warning relay (S-HORN).
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Security warning relay (S-HORN) terminal 2 - A-29 (SH)
|
Always
|
Below 1 Ω
|
Security warning relay (S-HORN) terminal 2 or A-29 (SH) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
OK
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (BATTERY - SECURITY WARNING RELAY [S-HORN])
|
(a) Remove the security warning relay (S-HORN).
|
|
*a
|
Front view of wire harness connector
(to Security Warning Relay [S-HORN])
|
|
|
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Switch Condition
|
Specified Condition
|
Security warning relay (S-HORN) terminal 1 - Body ground
|
Ignition switch off
|
11 to 14 V
|
Security warning relay (S-HORN) terminal 5 - Body ground
|
Ignition switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
6.
|
CHECK HARNESS AND CONNECTOR (SECURITY WARNING RELAY [S-HORN] - SECURITY HORN ASSEMBLY)
|
(a) Remove the security warning relay (S-HORN).
(b) Disconnect the A16 security horn assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Security warning relay (S-HORN) terminal 3 - A16-1
|
Always
|
Below 1 Ω
|
Security warning relay (S-HORN) terminal 3 or A16-1 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
7.
|
CHECK HARNESS AND CONNECTOR (SECURITY WARNING RELAY [S-HORN] - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
|
(a) Disconnect the 4A instrument panel junction block assembly connector.
(b) Remove the security warning relay (S-HORN).
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Security warning relay (S-HORN) terminal 2 - 4A-20
|
Always
|
Below 1 Ω
|
Security warning relay (S-HORN) terminal 2 or 4A-20 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|