Last Modified: 01-30-2024 6.11:8.1.0 Doc ID: RM100000001EKN2
Model Year Start: 2019 Model: RAV4 HV Prod Date Range: [11/2018 - 08/2020]
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P0C7917; Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]

DTC

P0C7917

Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold

DTC SUMMARY

MALFUNCTION DESCRIPTION

If an overvoltage malfunction occurs in the motor inverter or generator inverter, the motor generator control ECU (MG ECU) detects the malfunction and stores this DTC. The cause of this malfunction may be one of the following:

Area

Main Malfunction Description

Resolver

Open or short circuit in the motor resolver or generator resolver circuit

Hybrid vehicle transaxle assembly

  • Open or short circuit in the motor or generator coils
  • Motor (MG2) or generator (MG1) internal malfunction (iron particles or damage from foreign objects)

Inverter

  • Inverter internal circuit malfunction
  • Malfunction in ECU that controls the inverter
  • Malfunction in the sensors for inverter control (current sensor, voltage sensors (VH, VL), etc.)

HV battery

  • Open in system main relay circuit
  • Open in EV fuse circuit
  • Open in an HV floor under wire
  • HV battery malfunction

DESCRIPTION

For a description of the inverter.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P0D2D16,...,P0D2D1F; Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold+

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0C7917

Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold

Motor inverter overvoltage signal detected:

Overvoltage is detected after boosting.

A malfunction is detected in any of the motor components (motor inverter, motor, motor generator control ECU, etc.).

(1 trip detection logic)

  • Inverter with converter assembly
  • Hybrid vehicle transaxle assembly
  • Motor cable
  • HV battery junction block assembly
  • Service plug grip
  • Hybrid vehicle control ECU assembly
  • PCU fuse
  • Wire harness or connector
  • HV floor under wire

Comes on

Master Warning:

Comes on

Related Data List

DTC No.

Data List

P0C7917

  • Emergency Inverter Shut Down
  • VH Voltage

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): UTILITY

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. With power switch on (IG) and wait for 5 seconds or more.
  7. Turn the power switch on (READY) and wait for 5 seconds or more.
  8. Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

    NOTICE:

    As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.

  9. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  10. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE, perform driving pattern again.

WIRING DIAGRAM

Refer to the wiring diagram for the Generator Resolver Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Generator Resolver Circuit+

Refer to the wiring diagram for the Motor Resolver Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Motor Resolver Circuit+

Refer to the wiring diagram for the Generator High-voltage Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Generator High-voltage Circuit+

Refer to the wiring diagram for the Motor High-voltage Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Motor High-voltage Circuit+

Refer to the wiring diagram for the Inverter Low-voltage Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Inverter Low-voltage Circuit+

Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): HV Battery High-voltage Line Circuit+

CAUTION / NOTICE / HINT

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): PRECAUTION

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

    *a

    Without waiting for 10 minutes

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here 2019 - 2024 MY RAV4 RAV4 HV [11/2018 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION

PROCEDURE

1.

CHECK DTC OUTPUT

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.

(d) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes

Powertrain > Motor Generator > Trouble Codes

Result

Proceed to

P0C7917 only is output, or DTCs except the ones in the table below are also output.

A

DTCs of hybrid control system in the tables below are output.

B

DTCs of motor generator control system in the tables below are output.

C

Table 1

Malfunction Content

System

Relevant DTC

Insulation Malfunction

Hybrid control system

P1C7C49

Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure

P1C7D49

Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure

P1C7E49

Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure

P1C7F49

Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure

System Main Relay or High Voltage Circuit Malfunction

Hybrid control system

P0AD911

Hybrid/EV Battery Positive Contactor Circuit Short to Ground

P0AD915

Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open

P0ADD11

Hybrid/EV Battery Negative Contactor Circuit Short to Ground

P0ADD15

Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open

P1C8449

High Voltage Power Resource Circuit Short during Ready ON

HV Battery Malfunction

Hybrid control system

P0AFC16

Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold

P0AFC96

Hybrid/EV Battery Sensor Module Component Internal Failure

P1CBE1E

Hybrid/EV Battery Block 1 Voltage Difference Out of Range

P1CBF1E

Hybrid/EV Battery Block 2 Voltage Difference Out of Range

P1CC01E

Hybrid/EV Battery Block 3 Voltage Difference Out of Range

P1CC11E

Hybrid/EV Battery Block 4 Voltage Difference Out of Range

P1CC21E

Hybrid/EV Battery Block 5 Voltage Difference Out of Range

P1CC31E

Hybrid/EV Battery Block 6 Voltage Difference Out of Range

P1CC41E

Hybrid/EV Battery Block 7 Voltage Difference Out of Range

P1CC51E

Hybrid/EV Battery Block 8 Voltage Difference Out of Range

P1CC61E

Hybrid/EV Battery Block 9 Voltage Difference Out of Range

P1CC71E

Hybrid/EV Battery Block 10 Voltage Difference Out of Range

P1CFD1E

Hybrid/EV Battery Block 11 Voltage Difference Out of Range

P301100

Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme)

P301200

Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme)

P301300

Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme)

P301400

Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme)

P301500

Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme)

P301600

Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme)

P301700

Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme)

P301800

Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme)

P301900

Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme)

P302000

Hybrid/EV Battery Block 10 Circuit Resistance Out of Range (Extreme)

P302100

Hybrid/EV Battery Block 11 Circuit Resistance Out of Range (Extreme)

U029A87

Lost Communication with Hybrid/EV Battery Sensor Module Missing Message

Table 2

Malfunction Content

System

Relevant DTC

Microcomputer malfunction

Motor generator control system

P0A1A47

Generator Control Module Watchdog / Safety MC Failure

P0A1A49

Generator Control Module Internal Electronic Failure

P0A1B1F

Generator Control Module Circuit Intermittent

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

P313483

Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect

P313486

Communication Error from Drive Motor "A" to Generator Signal Invalid

P313487

Communication Error from Drive Motor "A" to Generator Missing Message

Hybrid control system

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

Power source circuit malfunction

Motor generator control system

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

Communication malfunction

Motor generator control system

P312487

Lost Communication between Drive Motor "A" and HV ECU Missing Message

Hybrid control system

P312387

Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message

Sensor and actuator circuit malfunction

Motor generator control system

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

P0A3F21

Drive Motor "A" Position Sensor Signal Amplitude < Minimum

P0A3F22

Drive Motor "A" Position Sensor Signal Amplitude > Maximum

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

P0A6012

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery

P0A6014

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open

P0A601C

Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range

P0A6312

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery

P0A6314

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open

P0A631C

Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range

P0BE512

Drive Motor "A" Phase U Current Sensor Circuit Short to Battery

P0BE514

Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open

P0BE528

Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BE912

Drive Motor "A" Phase V Current Sensor Circuit Short to Battery

P0BE914

Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open

P0BE928

Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BED12

Drive Motor "A" Phase W Current Sensor Circuit Short to Battery

P0BED14

Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open

P0BED28

Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BFD62

Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

P0DFA62

Generator Phase U-V-W Current Sensor Signal Compare Failure

P0E0012

Generator Phase U Current Sensor Circuit Short to Battery

P0E0014

Generator Phase U Current Sensor Circuit Short to Ground or Open

P0E0028

Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E0412

Generator Phase V Current Sensor Circuit Short to Battery

P0E0414

Generator Phase V Current Sensor Circuit Short to Ground or Open

P0E0428

Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E0812

Generator Phase W Current Sensor Circuit Short to Battery

P0E0814

Generator Phase W Current Sensor Circuit Short to Ground or Open

P0E0828

Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E3116

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold

P0E3117

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

P0E5128

DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E512A

DC/DC Converter Current Sensor Signal Stuck In Range

P1CAC49

Generator Position Sensor Internal Electronic Failure

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

P1CFF62

Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure

Hybrid control system

P0C7600

Hybrid/EV Battery System Discharge Time Too Long

P0D2D1C

Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range

P0E311C

Boosting Converter Voltage Sensor "A" Voltage Out of Range

System malfunction

Motor generator control system

P0A9000

Drive Motor "A" Performance

P0A9200

Hybrid Generator Performance

P0A949E

DC/DC Converter Stuck On

P0BFF1D

Drive Motor "A" Circuit Current Out of Range

P0C1900

Drive Motor "A" Execution Torque Performance

P0CA300

DC/DC Converter Step Up Voltage Performance

P0D3319

DC/DC Converter Circuit Current Above Threshold

P0E5717

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E7100

Generator Execution Torque Performance

P1CA51D

Hybrid Generator Circuit Current Out of Range

P1CB59E

DC/DC Converter Voltage Sensor "A" (VL) Stuck On

P314F1F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

P31531D

DC/DC Converter Current Sensor Circuit Current Out of Range

Hybrid control system

P0A9300

Inverter "A" Cooling System Performance

P0AA649

Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

P0C7396

Motor Electronics Coolant Pump "A" Component Internal Failure

P314A31

Motor Electronics Coolant Pump "A" No Signal

Table 3

Relevant DTC

P0A3F1F

Drive Motor "A" Position Sensor Circuit Intermittent

P0A4B1F

Generator Position Sensor Circuit Intermittent

P0A601F

Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent

P0A631F

Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent

P0BE51F

Drive Motor "A" Phase U Current Sensor Circuit Intermittent

P0BE91F

Drive Motor "A" Phase V Current Sensor Circuit Intermittent

P0BED1F

Drive Motor "A" Phase W Current Sensor Circuit Intermittent

P0C501F

Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent

P0C5A1F

Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent

P0C641F

Generator Position Sensor Circuit "A" Circuit Intermittent

P0C691F

Generator Position Sensor Circuit "B" Circuit Intermittent

P0D2D1F

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent

P0E001F

Generator Phase U Current Sensor Circuit Intermittent

P0E041F

Generator Phase V Current Sensor Circuit Intermittent

P0E081F

Generator Phase W Current Sensor Circuit Intermittent

P0E311F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

P0E511F

DC/DC Converter Current Sensor Circuit Intermittent

P1C601F

Generator Control Module Position Sensor REF Power Source Circuit Intermittent

P1C621F

Generator Control Module Offset Power Circuit Intermittent

P1C641F

Generator Control Module Circuit Intermittent

P1C651F

Generator Control Module Circuit Intermittent

P1C671F

Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent

P1C691F

Generator Phase U-V-W Current Sensor Circuit Intermittent

P31241F

Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent

HINT:

  • P0C7917 may be output as a result of the malfunction indicated by the DTCs above.
    1. The chart above is listed in inspection order of priority.
    2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)

(e) Turn the power switch off.

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM) 2019 - 2020 MY RAV4 HV [11/2018 - 06/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): DIAGNOSTIC TROUBLE CODE CHART 2020 MY RAV4 HV [06/2020 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): DIAGNOSTIC TROUBLE CODE CHART

C

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

A

2.

CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility

Tester Display

Diagnosis Related Information

(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes

(e) Read the diagnosis related information and freeze frame data of DTC P0C7917.

Result

Proceed to

DTC P312487 is listed in Diagnosis Related Information.

A

DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON.

B

Other than above

C

(f) Turn the power switch off.

A

GO TO DTC CHART (P312487)

B

GO TO DTC CHART (P321E9F)

C

3.

CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P033500,P033531; Crankshaft Position Sensor "A"+

Result

Proceed to

OK

A

NG (The connector is not connected securely.)

B

NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)

C

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

A

4.

CHECK GENERATOR RESOLVER CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Generator Resolver Circuit

NEXT

5.

CHECK MOTOR RESOLVER CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Motor Resolver Circuit

NEXT

6.

CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Generator High-voltage Circuit

NEXT

7.

CHECK MOTOR HIGH-VOLTAGE CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Motor High-voltage Circuit

NEXT

8.

CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): HV Battery High-voltage Line Circuit

NEXT

9.

CHECK INVERTER LOW-VOLTAGE CIRCUIT

Click here 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): Inverter Low-voltage Circuit

HINT:

If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.

NEXT

REPLACE INVERTER WITH CONVERTER ASSEMBLY 2019 MY RAV4 HV [11/2018 - 02/2019]; HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER (for 2WD): REMOVAL 2019 MY RAV4 HV [02/2019 - 10/2019]; HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER (for 2WD): REMOVAL 2020 MY RAV4 HV [10/2019 - 08/2020]; HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER (for 2WD): REMOVAL