Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001EKMX |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 08/2020] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P0A0011,P0A0015; Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020] |
DTC
|
P0A0011
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground
|
DTC
|
P0A0015
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open
|
DESCRIPTION
Refer to the description for DTC P0A001C.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A0011
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground
|
Short to ground detected in HV coolant temperature sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P0A0015
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open
|
Open or short to +B detected in HV coolant temperature sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
Related Data List
DTC No.
|
Data List
|
P0A0011
|
Inverter Coolant Temperature
|
P0A0015
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 5 seconds or more.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
CAUTION / NOTICE / HINT
HINT:
After the repair, clear the DTCs. If the value of Data List item "Inverter Coolant Temperature" is not abnormal (110°C (230°F) or -40°C (-40°F)) when the power switch is turned on (IG), the condition is judged as normal.
(If DTC P0A0011 is output, 110°C (230°F) will be displayed and if DTC P0A0015 is output, -40°C (-40°F) will be displayed.)
PROCEDURE
1.
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS
|
Click here
NEXT |
|
COMPLETED
|
|