Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001EEK3 |
Model Year Start: 2019 |
Model: RAV4 |
Prod Date Range: [11/2018 - 10/2023] |
Title: STOP AND START: STOP AND START SYSTEM: P060629; Backup Boost Converter "A" Control CPU Signal Invalid; 2019 - 2023 MY RAV4 [11/2018 - 10/2023] |
DTC
|
P060629
|
Backup Boost Converter "A" Control CPU Signal Invalid
|
DESCRIPTION
The engine stop and start ECU can detect open circuits when signals such as the boost, standby request or overheating signal cannot be sent to the backup boost converter control IC from the stop and start control IC in the engine stop and start ECU.
If a CPU duty malfunction is detected, the engine stop and start ECU stores DTC P060629 and blinks the stop and start cancel indicator.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Warning Indicate
|
Memory
|
Note
|
P060629
|
Backup Boost Converter "A" Control CPU Signal Invalid
|
The following condition continues for 1 second or more (2 trip detection logic):
-
CPU duty malfunction is detected.
|
-
Wire harness or connector
-
Engine stop and start ECU
|
Blinks
|
DTC stored
|
SAE Code: P0606
|
CONFIRMATION DRIVING PATTERN
HINT:
-
If the cable is disconnected from the battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle to complete the refresh charge. The refresh charge is complete when the Data List item "Status of Battery Charge Control" changes from "Refresh Charge Mode". (Usually, idling the engine for 5 to 60 minutes with the battery fluid temperature at 11°C (51°F) or higher, the refresh charge will be completed.)
-
If the Techstream is not available and the Data List item "Status of Battery Charge Control" cannot be checked, charge the battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
-
After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
-
Allow the engine to idle for 3 minutes after it is warmed up and check that the engine idle speed is within 50 rpm of the target idle speed.
CONFIRMATION AFTER TROUBLESHOOTING
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Clear the DTCs.
Powertrain > Stop and Start > Clear DTCs
(e) Start the engine and warm it up.
(f) Drive the vehicle at 7 km/h (4 mph) or more.
CAUTION:
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
(g) Depress the brake pedal and stop the vehicle.
(h) Keep the engine stopped by stop and start control for 1 second or more. (Keep the shift lever in D.)
(i) Release the brake pedal with the shift lever in D to start the engine.
(j) Check that DTCs are not output.
Powertrain > Stop and Start > Trouble Codes
STOP AND START SYSTEM OPERATION CHECK
HINT:
-
If the cable is disconnected from the battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle to complete the refresh charge. The refresh charge is complete when the Data List item "Status of Battery Charge Control" changes from "Refresh Charge Mode". (Usually, idling the engine for 5 to 60 minutes with the battery fluid temperature at 11°C (51°F) or higher, the refresh charge will be completed.)
-
If the Techstream is not available and the Data List item "Status of Battery Charge Control" cannot be checked, charge the battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
-
After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
(a) Start the engine and warm it up.
(b) Turn the air conditioning system off.
(c) Drive the vehicle at 7 km/h (4 mph) or more.
CAUTION:
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
(d) Depress the brake pedal and stop the vehicle.
(e) Allow the engine to stop by stop and start control. (Keep the shift lever in D.)
(f) Release the brake pedal with the shift lever in D to start the engine.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
HINT:
-
Using the Techstream, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click here
-
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click here
PROCEDURE
1.
|
CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BATTERY)
|
*a
|
Front view of wire harness connector
(to Engine Stop and Start ECU)
|
(a) Disconnect the engine stop and start ECU connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A33-1 (BIN2) - Body ground
|
Always
|
9.5 to 14 V
|
A33-3 (BIN1) - Body ground
|
Always
|
9.5 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BODY GROUND)
|
(a) Disconnect the engine stop and start ECU connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A33-2 (GND2) - Body ground
|
Always
|
Below 1 Ω
|
A33-8 (GND1) - Body ground
|
Always
|
Below 1 Ω
|
NG |
|