Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001Z00Y |
Model Year Start: 2022 |
Model: Avalon HV |
Prod Date Range: [08/2021 -
] |
Title: A25A-FXS (COOLING): THERMOSTAT: INSPECTION; 2022 MY Avalon HV [08/2021 - ] |
INSPECTION
PROCEDURE
1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
CAUTION:
-
Do not put your hands into the water that has been heated for the inspection.
-
Touching the heated water could result in burns.
HINT:
The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.
(a) Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
NOTICE:
Do not allow any water to come into contact with the connector of the water inlet with thermostat sub-assembly.
(b) Check that the valve of the water inlet with thermostat sub-assembly opens at the specified temperature.
Standard Valve Opening Temperature:
80 to 84°C (176 to 183°F)
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
(c) Check the valve lift.
Standard Valve Lift:
8.0 mm (0.315 in.) or more at 95°C (203°F)
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
|
|
(d) Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 72°C (162°F)).
If it is not fully closed, replace the water inlet with thermostat sub-assembly.
|