Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001RUIK |
Model Year Start: 2021 |
Model: Avalon |
Prod Date Range: [08/2020 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model): Recirculated/Fresh Air Modes Switch without User Input; 2021 - 2022 MY Avalon [08/2020 - ] |
Recirculated/Fresh Air Modes Switch without User Input
|
DESCRIPTION
If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
Symptom
|
Factor
|
-
Recirculation/fresh mode changes without permission
-
Recirculation/fresh mode light blinks
|
-
Customize setting*
-
Change in ambient air temperature
-
Decrease in refrigerant pressure
-
Air conditioner pressure sensor circuit malfunction
-
Engine coolant temperature (high)
|
PROCEDURE
Result
|
Proceed to
|
for USA and Canada
|
A
|
except USA and Canada
|
B
|
B
|
|
|
2.
|
CHECK CUSTOMIZE SETTING
|
(a) Using the Techstream, check that the customize setting Air Inlet Mode is not set to "Automatic".
Air Conditioner
Tester Display
|
Description
|
Default
|
Setting
|
ECU
|
Air Inlet Mode
|
Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly
|
Automatic
|
0:Automatic,1:Manual
|
Air conditioning amplifier assembly
|
OK:
Air Inlet Mode is not set to "Automatic".
NG |
|
CUSTOMIZE SETTING
Set Air Inlet Mode to "Manual"
|
OK
|
|
|
3.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Ambient Temp Sensor
|
Thermistor assembly
|
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Thermistor assembly circuit malfunction
-
When open circuit: -23.30°C (-9.94°F)
-
When short circuit: 65.95°C (150.71°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Ambient Temp Sensor
|
OK:
The value of the display does not change frequently.
OK
|
|
|
4.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / Engine / Data List.
(e) Read the Data List according to the display on the Techstream.
Powertrain > Engine > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Coolant Temperature
|
Engine coolant temperature
|
Min.: -40°C (-40°F), Max.: 140°C (284°F)
|
75 to 100°C (167 to 212°F): After warming up
|
This is the engine coolant temperature.
HINT:
-
After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
-
After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
-
If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
-
Check if the engine overheats if the value indicated is higher than 135°C (275°F).
|
Powertrain > Engine > Data List
Tester Display
|
Coolant Temperature
|
OK:
The value of the display does not change frequently.
NG |
|
GO TO COOLING SYSTEM
for 2GR-FKS: Click here
for A25A-FKS: Click here
|
OK
|
|
|
5.
|
CHECK REFRIGERANT PRESSURE
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
(f) Install a manifold gauge set.
(g) Read the manifold gauge pressure when the following conditions are met.
(1) Prepare the vehicle according to the table below.
Measurement Condition:
Item
|
Condition
|
Vehicle doors
|
Fully open
|
Temperature setting
|
MAX COLD
|
Blower speed
|
HI
|
A/C switch
|
On
|
Recirculation/fresh switch
|
RECIRCULATION
|
Interior temperature
|
25 to 35°C (77 to 95°F)
|
Standard Pressure:
Low pressure side
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High pressure side
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
(h) Compare the values displayed in the Data List and on the manifold gauge.
OK:
The values displayed in the Data List and on the manifold gauge match.
|