Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001RHEZ |
Model Year Start: 2021 |
Model: Avalon HV |
Prod Date Range: [08/2020 -
] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): P0BE528,...,P0BED28; Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; 2021 - 2022 MY Avalon HV [08/2020 - ] |
DTC
|
P0BE528
|
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
DTC
|
P0BE928
|
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
DTC
|
P0BED28
|
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction
-
Current sensor malfunction
-
Inverter with converter assembly internal circuit malfunction
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the motor inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0BE528
|
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Motor inverter current sensor U phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning Light:
Comes on
|
P0BE928
|
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Motor inverter current sensor V phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning Light:
Comes on
|
P0BED28
|
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Motor inverter current sensor W phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning Light:
Comes on
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a motor inverter current sensor U, V or W phase offset malfunction, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0BE6 (INF P0BE528): Offset malfunction
P0BEA (INF P0BE928): Offset malfunction
P0BEE (INF P0BED28): Offset malfunction
|
Required sensors/components
|
Motor inverter Phase U Current Sensor
Motor inverter Phase V Current Sensor
Motor inverter Phase W Current Sensor
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
1 driving cycle
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P0BE6 (INF P0BE528) is not detected
DTC P0BEA (INF P0BE928) is not detected
DTC P0BEE (INF P0BED28) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 5 seconds or more. [*1]
-
Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Powertrain > Motor Generator > Trouble Codes
Result
|
Proceed to
|
P0BE528, P0BE928 or P0BED28 only is output, or DTCs except the ones in the table below are also output.
|
A
|
DTCs of hybrid control system in the table below are output.
|
B
|
DTCs of motor generator control system in the table below are output.
|
C
|
Table 1
Malfunction Content
|
System
|
Relevant DTC
|
Insulation Malfunction
|
Hybrid control system
|
P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
P1C7D49
|
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
|
P1C7E49
|
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
|
P1C7F49
|
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
|
High voltage system malfunction
|
Hybrid control system
|
P0AA649
|
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure
|
Table 2
Malfunction Content
|
System
|
Relevant DTC
|
Microcomputer malfunction
|
Hybrid control system
|
P0A1B49
|
Drive Motor "A" Control Module Internal Electronic Failure
|
Motor generator control system
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
Power source circuit malfunction
|
Motor generator control system
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
Communication malfunction
|
Motor generator control system
|
P312487
|
Lost Communication between Drive Motor "A" and HV ECU Missing Message
|
Sensor and actuator circuit malfunction
|
Motor generator control system
|
P0A3F16
|
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
|
P0A3F21
|
Drive Motor "A" Position Sensor Signal Amplitude < Minimum
|
P0A3F22
|
Drive Motor "A" Position Sensor Signal Amplitude > Maximum
|
P0C5013
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Open
|
P0C5016
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C5017
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C5A13
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Open
|
P0C5A16
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C5A17
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0D2D16
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
|
P0D2D17
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
|
P1CAD49
|
Drive Motor "A" Position Sensor Internal Electronic Failure
|
P1CB038
|
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
|
System malfunction
|
Motor generator control system
|
P0A7873
|
Drive Motor "A" Inverter Actuator Stuck Closed
|
HINT:
-
P0BE528, P0BE928 or P0BED28 may be output as a result of the malfunction indicated by the DTCs above.
-
The chart above is listed in inspection order of priority.
-
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
A
|
|
|
2.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|