Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001RHEN |
Model Year Start: 2021 |
Model: Avalon HV |
Prod Date Range: [08/2020 -
] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): P0A0011,P0A0015; Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; 2021 - 2022 MY Avalon HV [08/2020 - ] |
DTC
|
P0A0011
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground
|
DTC
|
P0A0015
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open
|
DESCRIPTION
Refer to the description for DTC P0A001C.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A0011
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground
|
Short to ground detected in HV coolant temperature sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning Light:
Comes on
|
P0A0015
|
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open
|
Open or short to +B detected in HV coolant temperature sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning Light:
Comes on
|
Related Data List
DTC No.
|
Data List
|
P0A0011
|
Inverter Coolant Temperature
|
P0A0015
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction in the HV coolant temperature sensor it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0A02 (INF P0A0011): Motor Electronics Coolant Temperature Sensor Range check (Low voltage)
P0A03 (INF P0A0015): Motor Electronics Coolant Temperature Sensor Range check (High voltage)
|
Required sensors/components
|
HV coolant temperature sensor
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
Immediately
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P0A02 (INF P0A0011) is not detected
DTC P0A03 (INF P0A0015) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
HINT:
After the repair, clear the DTCs. If the value of Data List item "Inverter Coolant Temperature" is not abnormal (110°C (230°F) or -40°C (-40°F)) when the power switch is turned on (IG), the condition is judged as normal.
(If DTC P0A0011 is output, 110°C (230°F) will be displayed and if DTC P0A0015 is output, -40°C (-40°F) will be displayed.)
PROCEDURE
1.
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS
|
Click here
NEXT |
|
COMPLETED
|
|