Prod Date Range: [08/2020 -
] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): P062F46; Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure; 2021 - 2022 MY Avalon HV [08/2020 - ] |
DTC
|
P062F46
|
Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure
|
DESCRIPTION
The inverter with converter assembly monitors its internal operation and will store this DTC if it detects a malfunction of its EEPROM.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P062F46
|
Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure
|
ECU internal malfunction
(EEPROM error)
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning Light:
Comes on
|
MONITOR DESCRIPTION
The motor generator control ECU monitors its internal operation. If the internal operation is malfunctioning, the motor generator control ECU illuminates the MIL and stores a DTC.
MONITOR STRATEGY
Related DTCs
|
P062F (INF P062F46): Internal Control Module EEPROM (Drive Motor "A" Control Module)
|
Required sensors/components
|
Motor generator control ECU
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
1 driving cycle
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P062F (INF P062F46) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 15 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
PROCEDURE
1.
|
CHECK DTC OUTPUT (HEALTH CHECK)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: System Select / Health Check.
(d) Check for DTCs.
Result
|
Proceed to
|
P062F46 is output from the motor generator control system.
|
A
|
P062F46 is output from any system other than the motor generator control system.
|
B
|
(e) Turn the power switch off.
B |
|