REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water by-pass hose assembly) removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedure
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane Departure Alert System (w/ Steering Control)
|
|
Pre-collision System
|
Intelligent Clearance Sonar System*1
|
Lighting System (for Gasoline Model with Cornering Light)
|
Memorize steering angle neutral point
|
Parking Assist Monitor System
|
|
Panoramic View Monitor System
|
|
Replacement of ECM
|
Vehicle Identification Number (VIN) registration
|
MIL comes on
|
|
ECU communication ID registration (Immobiliser system)
|
Engine start function
|
|
Code registration (Smart Key System (for Start Function, Gasoline Model))
|
-
Wireless Door Lock Control System
-
Smart Key System (for Entry Function, Gasoline Model)
-
Smart Key System (for Start Function, Gasoline Model)
-
Steering lock function
|
Replacement of ECM
(If transaxle compensation code read from ECM)
|
-
Perform reset memory*2
-
Transfer transaxle compensation code
-
Perform road test to allow ECM to learn
|
-
Large shift shock
-
Deterioration of fuel efficiency
|
for UB80F Initialization
for UB80F Registration
|
Replacement of ECM
(If transaxle compensation code not read from ECM)
|
-
Perform reset memory*2
-
Reset transaxle compensation code
-
Perform road test to allow ECM to learn
|
PROCEDURE
1. REMOVE FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE)
Click here
2. REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
(a) Disengage the clamp to disconnect the vacuum hose from the engine wire harness.
|
|
(b) Disconnect the 3 connectors.
|
|
(c) Disengage the clamp to disconnect the engine wire harness from the water hose clamp bracket.
(d) Disconnect the outlet heater hose connector from the No. 2 water by-pass pipe sub-assembly.
NOTICE:
Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater hose connector before performing this work.
(1) Pull out the retainer to disengage the lock claws and pull off the outlet heater hose connector.
*a
|
Retainer
|
|
Pull out
|
|
Pull off
|
(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
(3) Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater hose connector with plastic bags to prevent damage and contamination.
(e) Disconnect the inlet heater hose connector from the flow shutting valve (water by-pass hose assembly).
NOTICE:
Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector before performing this work.
(1) Pull out the retainer to disengage the lock claws and pull off the inlet heater hose connector.
*a
|
Retainer
|
|
Pull out
|
|
Pull off
|
(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
(3) Cover the disconnected inlet heater hose connector with a plastic bag to prevent damage and contamination.
(f) Remove the bolt to disconnect the No. 2 water by-pass pipe sub-assembly.
|
|
(g) Remove the bolt to disconnect the flow shutting valve (water by-pass hose assembly).
|
|
(h) Disengage the 2 clamps to disconnect the wire harness.
|
|
(i) Remove the 2 bolts and the water hose clamp bracket.
|
|
(j) Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the water by-pass outlet sub-assembly.
HINT:
Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and water by-pass outlet sub-assembly.
|
|
(k) Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the transmission oil cooler.
HINT:
Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and transmission oil cooler.
|
|
|