| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) | Actual cabin temperature displayed | Cooler (room temp. sensor) thermistor circuit malfunction 
                                 
                                    
When open circuit: -6.50°C (20.30°F)
When short circuit: 57.25°C (135.05°F)
 | 
                        
                           | Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | Thermistor assembly circuit malfunction 
                                 
                                    
When open circuit: -23.30°C (-9.94°F)
When short circuit: 65.95°C (150.71°F)
 | 
                        
                           | Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) | Adjust ambient temperature displayed | Air conditioning amplifier assembly malfunction | 
                        
                           | Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction 
                                 
                                    
When open circuit: -29.70°C (-21.46°F)
When short circuit: 59.55°C (139.19°F)
 | 
                        
                           | Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) | Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction 
                                 
                                    
When open circuit: -327.68°C (-557.82°F)
When short circuit: 327.67°C (621.81°F)
 | 
                        
                           | Solar Sensor (D Side) | Driver side automatic light control sensor | Min.: 0 Max.: 255 | Driver side automatic light control sensor value increases as brightness increases | Driver side automatic light control sensor circuit malfunction 
                                 
                                    
When open circuit: 0
When short circuit: 255
 | 
                        
                           | Solar Sensor (P Side) | Front passenger side automatic light control sensor | Min.: 0 Max.: 255 | Front passenger side automatic light control sensor value increases as brightness increases | Front passenger side automatic light control sensor circuit malfunction 
                                 
                                    
When open circuit: 0
When short circuit: 255
 | 
                        
                           | Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed | 
                                 
                                    
SFI system malfunction
CAN communication system malfunction
 | 
                        
                           | Blower Motor Speed Level | Blower motor speed level | Min.: 0 Max.: 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction | 
                        
                           | Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG Max.: 3294.37 kPaG | Actual refrigerant pressure displayed | 
                                 
                                    
Refrigerant line (gas leak etc.)
Air conditioner pressure sensor circuit malfunction
 | 
                        
                           | Air Outlet Servo Pulse (R) | No. 2 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE: 260 (pulse)
B/L: 212 (pulse)
FOOT: 182 (pulse)
F/D: 220 (pulse)
SHUT: 158 (pulse)
D/F: 177 (pulse)
 | No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction | 
                        
                           | Air Outlet Servo Actual Pls(R) | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE: 260 (pulse)
B/L: 212 (pulse)
FOOT: 182 (pulse)
F/D: 220 (pulse)
SHUT: 158 (pulse)
D/F: 177 (pulse)
 | No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction | 
                        
                           | Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
MAX COLD: 257 (pulse)
MAX HOT: 165 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction | 
                        
                           | Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
MAX COLD: 257 (pulse)
MAX HOT: 165 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction | 
                        
                           | Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
MAX COLD: 255 (pulse)
MAX HOT: 347 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction | 
                        
                           | Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
MAX COLD: 255 (pulse)
MAX HOT: 347 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction | 
                        
                           | Air Outlet Servo Pulse (D) | No. 3 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE-R: 271 (pulse)
FACE: 256 (pulse)
FACE1: 256 (pulse)
FACE2: 256 (pulse)
B/L: 245 (pulse)
B/L2: 245 (pulse)
FOOT-R: 207 (pulse)
FOOT: 215 (pulse)
FOOT-D: 207 (pulse)
FOOT-0: 224 (pulse)
F/D: 192 (pulse)
DEF-FOOT: 173 (pulse)
DEF or SHUT: 164 (pulse)
S-FLOW: 278 (pulse)
 | No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction | 
                        
                           | Air Outlet Servo Actu Pulse(D) | No. 3 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE-R: 271 (pulse)
FACE: 256 (pulse)
FACE1: 256 (pulse)
FACE2: 256 (pulse)
B/L: 245 (pulse)
B/L2: 245 (pulse)
FOOT-R: 207 (pulse)
FOOT: 215 (pulse)
FOOT-D: 207 (pulse)
FOOT-0: 224 (pulse)
F/D: 192 (pulse)
DEF-FOOT: 173 (pulse)
DEF or SHUT: 164 (pulse)
S-FLOW: 278 (pulse)
 | No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction | 
                        
                           | Air Outlet Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE-R: 241 (pulse)
FACE: 256 (pulse)
FACE1: 256 (pulse)
FACE2: 256 (pulse)
B/L: 267 (pulse)
B/L2: 267 (pulse)
FOOT-R: 305 (pulse)
FOOT: 297 (pulse)
FOOT-D: 305 (pulse)
FOOT-0: 288 (pulse)
F/D: 320 (pulse)
DEF-FOOT: 339 (pulse)
DEF or SHUT: 348 (pulse)
S-FLOW: 234 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction | 
                        
                           | Air Outlet Servo Actu Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
FACE-R: 241 (pulse)
FACE: 256 (pulse)
FACE1: 256 (pulse)
FACE2: 256 (pulse)
B/L: 267 (pulse)
B/L2: 267 (pulse)
FOOT-R: 305 (pulse)
FOOT: 297 (pulse)
FOOT-D: 305 (pulse)
FOOT-0: 288 (pulse)
F/D: 320 (pulse)
DEF-FOOT: 339 (pulse)
DEF or SHUT: 348 (pulse)
S-FLOW: 234 (pulse)
 | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction | 
                        
                           | Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128 Max.: 383 | 
                                 
                                    
Recirculation: 256 (pulse)
Fresh: 220 (pulse)
 | No. 1 blower damper servo sub-assembly circuit malfunction | 
                        
                           | Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 | 
                                 
                                    
Recirculation: 256 (pulse)
Fresh: 220 (pulse)
 | No. 1 blower damper servo sub-assembly circuit malfunction | 
                        
                           | Compressor Speed | Compressor speed | Min.: 0 rpm Max.: 65535 rpm | Actual compressor speed displayed | - | 
                        
                           | Compressor Target Speed | Compressor target speed | Min.: 0 rpm Max.: 65535 rpm | Compressor target speed displayed | - | 
                        
                           | Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr or 2C incr | Customized value displayed | - | 
                        
                           | Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | *1 | 
                        
                           | Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - | 
                        
                           | Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF or ON | Customized value displayed | - | 
                        
                           | ECO MODE Cancel | Function to cancel ECO mode when set to ON | OFF or ON | Customized value displayed | - | 
                        
                           | ECO Switch | ECO switch assembly (electric parking brake switch assembly) | OFF or ON | OFF: ECO switch assembly (electric parking brake switch assembly) not pushed ON: ECO switch assembly (electric parking brake switch assembly) pushed and held | ECO switch assembly (electric parking brake switch assembly) circuit malfunction | 
                        
                           | Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - | 
                        
                           | Fan speed increment control | Fan speed increment control | Slow, Normal or Fast | Customized value displayed | - | 
                        
                           | Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - | 
                        
                           | Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - | 
                        
                           | Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr | Customized value displayed | - | 
                        
                           | Compressor Drive Check | Compressor drive check | OK or NG | OK: Compressor drives NG: Compressor does not drive | - | 
                        
                           | Glass Temperature | - | - | - | - | 
                        
                           | Glass Surroundings Temperature | - | - | - | - | 
                        
                           | Glass Humidity | - | - | - | - | 
                        
                           | Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - | 
                        
                           | Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD Max.: MAX HOT | Driver side set temperature displayed | - | 
                        
                           | Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD Max.: MAX HOT | Front passenger side set temperature displayed | - | 
                        
                           | Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - | 
                        
                           | S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - | 
                        
                           | Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 | Number of DTCs displayed | - | 
                        
                           | Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0 Max.: 255 | Number of times refrigerant high pressure history stored displayed | *2 |