Last Modified: 08-21-2023 6.11:8.1.0 Doc ID: RM100000001PTIN
Model Year Start: 2021 Model: Avalon Prod Date Range: [08/2020 -           ]
Title: A25A-FKS (BATTERY / CHARGING): GENERATOR: ON-VEHICLE INSPECTION; 2021 - 2022 MY Avalon [08/2020 -        ]

ON-VEHICLE INSPECTION

CAUTION / NOTICE / HINT

NOTICE:

  • Do not remove the generator pulley cap.
  • If the generator pulley cap is removed, replace the generator pulley cap and generator pulley with clutch with new ones as the correct grease amount cannot be confirmed.

HINT:

If it is confirmed that the generator assembly is not generating power, it is not necessary to perform the counterclockwise check as another malfunction is suspected.

PROCEDURE

1. REMOVE V-RIBBED BELT

Click here 2021 - 2022 MY Avalon [08/2020 -        ]; MAINTENANCE: A25A-FKS DRIVE BELT: REMOVAL

2. INSPECT GENERATOR PULLEY WITH CLUTCH

(a) Check that the generator pulley with clutch operates in accordance with the following table.

Counterclockwise

Clockwise

Standard:

Counterclockwise

Clockwise

Spins Freely

Lock

HINT:

If the generator pulley with clutch does not turn smoothly, does not operate as specified, or an abnormal sound is output, replace it with a new one.

3. INSTALL V-RIBBED BELT

Click here 2021 - 2022 MY Avalon [08/2020 -        ]; MAINTENANCE: A25A-FKS DRIVE BELT: INSTALLATION