Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001JTC9 |
Model Year Start: 2020 |
Model: Avalon HV |
Prod Date Range: [08/2019 - 08/2021] |
Title: MAINTENANCE: A25A-FXS AUXILIARY BATTERY: REMOVAL; 2020 - 2021 MY Avalon HV [08/2019 - 08/2021] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during auxiliary battery removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedure
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Auxiliary battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane departure alert system (w/ Steering Control)
|
|
Pre-collision system
|
Intelligent clearance sonar system*
|
Lighting System (for HV Model with Cornering Light)
|
Memorize steering angle neutral point
|
Parking assist monitor system
|
|
Panoramic view monitor system
|
|
PROCEDURE
1. PRECAUTION
NOTICE:
-
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
-
When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions and same capacity or more from the same class at a 20-hour rate.
-
After replacing the auxiliary battery, install the ventilation hole plug supplied with the new auxiliary battery or the ventilation hole plug from the old auxiliary battery to the ventilation hole on the side to which the battery hose is not connected.
2. REMOVE LUGGAGE TRIM SERVICE HOLE COVER
(a) Disengage the claw and remove the luggage trim service hole cover.
|
|
3. DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
(a) Loosen the nut, and disconnect the cable from the negative (-) auxiliary battery terminal.
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click here
|
|
4. REMOVE AUXILIARY BATTERY
(a) Disengage the 2 claws and open the battery terminal connector cover in the order shown in the illustration.
|
|
(b) Loosen the nut and disconnect the cable from the positive (+) auxiliary battery terminal.
|
|
(c) Disconnect the battery hose from the auxiliary battery.
|
|
(d) Remove the bolt and remove the No. 3 battery clamp as shown in the illustration.
|
Remove in this Direction
|
(e) Remove the auxiliary battery.
|