                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001BX41 |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 -                    
                                       ] |  
                        | Title: PARK ASSIST / MONITORING: BLIND SPOT MONITOR SYSTEM(for HV Model): Power Source Circuit; 2019 - 2022 MY Avalon HV [04/2018 -        ] |  DESCRIPTIONThis circuit provides power to operate the blind spot monitor sensor. WIRING DIAGRAM  CAUTION / NOTICE / HINTNOTICE: Inspect the fuses for circuits related to this system before performing the following procedure. PROCEDURE
                     
                        
                           | 1.  | CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH POWER SOURCE) |  (a) Disconnect the P5 blind spot monitor sensor RH connector. (b) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | P5-5 (BRB) - Body ground | Power switch on (IG) | 11 to 14 V |  
                           | P5-5 (BRB) - Body ground | Power switch off | Below 1 V |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 2.  | CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | P5-10 (BRGD) - Body ground | Always | Below 1 Ω |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 3.  | CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH POWER SOURCE) |  (a) Disconnect the P6 blind spot monitor sensor LH connector. (b) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | P6-5 (BLB) - Body ground | Power switch on (IG) | 11 to 14 V |  
                           | P6-5 (BLB) - Body ground | Power switch off | Below 1 V |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 4.  | CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | P6-10 (BLGD) - Body ground | Always | Below 1 Ω |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  |