Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001B7KN |
Model Year Start: 2019 |
Model: Avalon HV |
Prod Date Range: [04/2018 -
] |
Title: LIGHTING (INT): LIGHTING SYSTEM (for HV Model): Power Switch Illumination Circuit; 2019 - 2022 MY Avalon HV [04/2018 - ] |
Power Switch Illumination Circuit
|
DESCRIPTION
The illuminated entry system controls the power switch illumination.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
Before replacing the certification ECU (smart key ECU assembly), refer to Registration.
Click here
PROCEDURE
1.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Smart Key / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Smart Key > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Power/Engine SW Light
|
Power switch illumination
|
OFF or ON
|
-
|
Body Electrical > Smart Key > Active Test
Tester Display
|
Power/Engine SW Light
|
OK:
Power switch illumination comes on.
NG
|
|
|
(a) Remove the power switch.
Click here
(b) Inspect the power switch.
Click here
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (POWER SWITCH - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY))
|
(a) Disconnect the G40 certification ECU (smart key ECU assembly) connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
G117-9 (SWIL) - G40-10 (SWIL)
|
Always
|
Below 1 Ω
|
G117-6 (AGND) - G40-11 (AGND)
|
Always
|
Below 1 Ω
|
G117-9 (SWIL) or G40-10 (SWIL) - Body ground
|
Always
|
10 kΩ or higher
|
G117-6 (AGND) or G40-11 (AGND) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|