| (2) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Float Level | Specified Condition |  
                                       | 1 - 2 | F | 4.255 to 4.605 V* |  
                                       | Between F and E | 0.345 to 4.605 V* (Gradually changes) |  
                                       | E | 0.345 to 0.695 V* |  *: The output voltage changes depending on the voltage applied to the terminals. Output voltage (F) = (0.851 x Voltage applied to terminals) to (0.921 x Voltage applied to terminals) Output voltage (E) = (0.069 x Voltage applied to terminals) to (0.139 x Voltage applied to terminals) If the result is not as specified, replace the fuel sender gauge assembly. |