Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001B4DV |
Model Year Start: 2019 |
Model: Avalon HV |
Prod Date Range: [04/2018 -
] |
Title: A25A-FXS (ENGINE CONTROL): SFI SYSTEM: P26CA14; Engine Coolant Pump Circuit Short to Ground or Open; 2019 - 2022 MY Avalon HV [04/2018 - ] |
DTC
|
P26CA14
|
Engine Coolant Pump Circuit Short to Ground or Open
|
DESCRIPTION
Refer to DTC P26CA12.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P26CA14
|
Engine Coolant Pump Circuit Short to Ground or Open
|
The operation duty ratio (WPO) of the monitoring water inlet housing with water pump sub-assembly becomes a certain amount or less when water inlet housing with water pump sub-assembly operation command is output (1 trip detection logic).
|
-
Open or short in water inlet housing with water pump sub-assembly circuit
-
Water inlet housing with water pump sub-assembly
-
ECM
|
Comes on
|
DTC stored
|
SAE Code: P26CC
|
Related Data List
DTC No.
|
Data List
|
P26CA14
|
-
Coolant Temperature
-
Electric Water Pump Target Speed
-
Electric Water Pump Speed
|
MONITOR DESCRIPTION
The ECM outputs an operation duty signal (WPO) to steplessly control the speed of the water inlet housing with water pump sub-assembly. The ECM outputs an operation duty signal (WPO) to the water inlet housing with water pump sub-assembly and monitors the actual duty signal (WPO) being output. When the operation duty signal (WPO) is being output to the to the water inlet housing with water pump sub-assembly and the actual operation duty signal (WPO) is a certain value or less, the ECM detects a malfunction and stores a DTC.
MONITOR STRATEGY
Related DTCs
|
P26CC: Engine water pump circuit range check (Low voltage)
|
Required Sensors/Components (Main)
|
Water inlet housing with water pump sub-assembly
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Continuous
|
Duration
|
3 seconds
|
MIL Operation
|
Immediate
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
All of the following conditions are met
|
-
|
Auxiliary battery voltage
|
8 V or higher
|
Power switch
|
On (IG)
|
Time after power switch off to on (IG)
|
0.5 seconds or more
|
Output duty cycle
|
30 to 85%
|
Engine water pump circuit pulse input fail (P26CA)
|
Not detected
|
TYPICAL MALFUNCTION THRESHOLDS
Both of the following conditions are met
|
-
|
Water inlet housing with water pump sub-assembly output terminal voltage level
|
Low
|
Water inlet housing with water pump sub-assembly output signal
|
No signal
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG).
-
Turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for at least 30 seconds.
-
Turn the power switch on (IG) [A].
-
Turn the Techstream on.
-
Put the engine in Inspection Mode (Maintenance Mode).
Click here
-
Start the engine and maintain the engine speed at 2500 rpm or more for at least 40 seconds [B].
-
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
-
Read the pending DTCs.
HINT:
-
If a pending DTC is output, the system is malfunctioning.
-
If a pending DTC is not output, perform the following procedure.
-
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
-
Input the DTC: P26CA14.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
WIRING DIAGRAM
Refer to DTC P26CA12.
Click here
CAUTION / NOTICE / HINT
HINT:
Read Freeze Frame Data using the Techstream. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
1.
|
INSPECT ECM (INTERNAL CIRCUIT)
|
*a
|
Front view of wire harness connector
(to Water Inlet Housing with Water Pump Sub-assembly)
|
(a) Disconnect the water inlet housing with water pump sub-assembly connector.
(b) Turn the power switch on (IG).
(c) Measure the resistance according to the value(s) in the table below.
Standard:
Tester Connection
|
Condition
|
Specified Condition
|
C39-2 (SWP) - Body ground
|
Power switch on (IG)
|
Resistance fluctuates*
|
HINT:
-
*: When the connector of the water inlet housing with water pump sub-assembly is disconnected, the ECM will enter fail-safe mode. When the ECM is in fail-safe mode, a continuous duty signal will be output and the resistance will fluctuate as the transistor inside the ECM is turned on an off.
-
If the resistance fluctuates while the ECM is in fail-safe mode after the connector of the water inlet housing with water pump sub-assembly is disconnected, it can be determined that the transistor is operating.
-
If the transistor does not operate, the ECM may be malfunctioning.
-
If the resistance fluctuates after turning the power switch on (IG), it can be determined that the ECM is in fail-safe mode.
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (WATER INLET HOUSING WITH WATER PUMP SUB-ASSEMBLY - ECM)
|
(a) Disconnect the water inlet housing with water pump sub-assembly connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C39-2 (SWP) - C55-50 (WPO)
|
Always
|
Below 1 Ω
|
C39-2 (SWP) or C55-50 (WPO) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|