INSTALLATION
PROCEDURE
1. INSTALL FRONT CORNER ULTRASONIC SENSOR
HINT:
-
Use the same procedure for the RH side and LH side.
-
The following procedure is for the LH side.
(a) Engage the 2 claws to install the front corner ultrasonic sensor as shown in the illustration.
|
Install in this Direction
|
(b) Connect the connector.
2. INSTALL FRONT CENTER ULTRASONIC SENSOR
HINT:
-
Use the same procedure for the RH side and LH side.
-
The following procedure is for the LH side.
(a) Engage the 2 claws to install the front center ultrasonic sensor as shown in the illustration.
|
Install in this Direction
|
(b) Connect the connector.
3. INSTALL FRONT BUMPER ASSEMBLY
Click here
4. PERFORM CALIBRATION
for Gasoline Model: Click here
for HV Model: Click here
SST: 09989-00020
|