                        | Title: LIGHTING (EXT): RELAY: ON-VEHICLE INSPECTION; 2019 - 2022 MY Avalon Avalon HV [04/2018 -        ] |  ON-VEHICLE INSPECTIONPROCEDURE1. INSPECT H-LP LH RELAY   
                     
                        
                        
                     
                     
                        
                           | *a | Component without harness connected (H-LP LH Relay) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |  
                           | 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |  If the result is not as specified, replace the H-LP LH relay. 2. INSPECT H-LP RH RELAY   
                     
                        
                        
                     
                     
                        
                           | *a | Component without harness connected (H-LP RH Relay) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |  
                           | 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |  If the result is not as specified, replace the H-LP RH relay. 3. INSPECT DIM RELAY (w/o Cornering Light)   
                     
                        
                        
                     
                     
                        
                           | *a | Component without harness connected (DIM Relay) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |  
                           | 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |  If the result is not as specified, replace the DIM relay. 4. INSPECT DRL RELAY (w/o Cornering Light)   
                     
                        
                        
                     
                     
                        
                           | *a | Component without harness connected (DRL Relay) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |  
                           | 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |  If the result is not as specified, replace the DRL relay. |