Last Modified: 08-21-2023 6.11:8.1.0 Doc ID: RM100000001B1NQ
Model Year Start: 2019 Model: Avalon HV Prod Date Range: [04/2018 -           ]
Title: LIGHTING (EXT): RELAY: ON-VEHICLE INSPECTION; 2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]

ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT H-LP LH RELAY

*a

Component without harness connected

(H-LP LH Relay)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Voltage not applied between terminals 1 and 2

10 kΩ or higher

3 - 5

Voltage applied between terminals 1 and 2

Below 1 Ω

If the result is not as specified, replace the H-LP LH relay.

2. INSPECT H-LP RH RELAY

*a

Component without harness connected

(H-LP RH Relay)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Voltage not applied between terminals 1 and 2

10 kΩ or higher

3 - 5

Voltage applied between terminals 1 and 2

Below 1 Ω

If the result is not as specified, replace the H-LP RH relay.

3. INSPECT DIM RELAY (w/o Cornering Light)

*a

Component without harness connected

(DIM Relay)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Voltage not applied between terminals 1 and 2

10 kΩ or higher

3 - 5

Voltage applied between terminals 1 and 2

Below 1 Ω

If the result is not as specified, replace the DIM relay.

4. INSPECT DRL RELAY (w/o Cornering Light)

*a

Component without harness connected

(DRL Relay)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Voltage not applied between terminals 1 and 2

10 kΩ or higher

3 - 5

Voltage applied between terminals 1 and 2

Below 1 Ω

If the result is not as specified, replace the DRL relay.