| (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | 4 (RV) - 1 (E) | Light control rheostat up switch pressed | Below 50 Ω |  
                                       | Light control rheostat up switch not pressed | 10 kΩ or higher |  
                                       | Light control rheostat down switch pressed | 1.71 to 1.94 kΩ |  
                                       | Light control rheostat down switch not pressed | 10 kΩ or higher |  
                                       | 3 (A/B) - 1 (E) | ODO/TRIP switch pressed | Below 50 Ω |  
                                       | ODO/TRIP switch not pressed | 10 kΩ or higher |  If the result is not as specified, replace the trip switch. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Component without harness connected (Trip Switch) |  |  |