Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001AYSC |
Model Year Start: 2019 |
Model: Avalon |
Prod Date Range: [04/2018 -
] |
Title: 2GR-FKS (ENGINE CONTROL): ECM: INSTALLATION; 2019 - 2022 MY Avalon [04/2018 - ] |
INSTALLATION
PROCEDURE
1. INSTALL NO. 2 ECM BRACKET
(a) Install the No. 2 ECM bracket to the ECM with the 2 screws.
Torque:
4.5 N·m {46 kgf·cm, 40 in·lbf}
2. INSTALL NO. 1 ECM BRACKET
(a) Install the No. 1 ECM bracket to the ECM with the 2 screws.
Torque:
4.5 N·m {46 kgf·cm, 40 in·lbf}
3. INSTALL ECM
(a) Install the ECM with the 2 bolts and nut.
Torque:
8.0 N·m {82 kgf·cm, 71 in·lbf}
NOTICE:
If the ECM has been struck or dropped, replace it.
(b) Connect the 2 ECM connectors and rotate the 2 levers to lock them.
NOTICE:
-
When connecting the ECM connectors, make sure that the connecting parts of the ECM connectors are free of dirt, water and other foreign matter.
-
Be sure to securely connect the ECM connectors.
|
|
4. INSTALL AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE
Click here
5. INSTALL INLET AIR CLEANER ASSEMBLY
Click here
6. INSTALL COOL AIR INTAKE DUCT SEAL
Click here
7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Click here
8. PERFORM INITIALIZATION
Click here
|