| (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |  
                                       | 15°C (59°F) | 2.45 to 2.88 kΩ |  
                                       | 20°C (68°F) | 1.95 to 2.30 kΩ |  
                                       | 25°C (77°F) | 1.60 to 1.80 kΩ |  
                                       | 30°C (86°F) | 1.28 to 1.47 kΩ |  
                                       | 35°C (95°F) | 1.00 to 1.22 kΩ |  
                                       | 40°C (104°F) | 0.80 to 1.00 kΩ |  
                                       | 45°C (113°F) | 0.65 to 0.85 kΩ |  
                                       | 50°C (122°F) | 0.50 to 0.70 kΩ |  
                                       | 55°C (131°F) | 0.44 to 0.60 kΩ |  
                                       | 60°C (140°F) | 0.36 to 0.50 kΩ |  
                                 NOTICE: 
                                    
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
 HINT: As the temperature increases, the resistance decreases (see the graph). If the result is not as specified, replace the thermistor assembly. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Component without harness connected (Thermistor Assembly) |  
                                                | *b | Sensing Portion |  
                                                | *c | Resistance (kΩ) |  
                                                | *d | Temperature (°C (°F)) |  
                                                | *e | Allowable Range |  |  |