| (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  for LH Side
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | 1 (RAL+) - 3 (RAL-) | 15 to 25°C | 3.3 to 3.7 Ω |  for RH Side
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | 1 (RAR+) - 3 (RAR-) | 15 to 25°C | 3.3 to 3.7 Ω |  If the result is not as specified, replace the rear shock absorber assembly. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *A | for LH Side |  
                                                | *B | for RH Side |  
                                                | *a | Component without harness connected (Absorber Control Actuator) |  |  |