FR Speed Open
|
Front speed sensor RH open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
FL Speed Open
|
Front speed sensor LH open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
RR Speed Open
|
Rear speed sensor RH open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
RL Speed Open
|
Rear speed sensor LH open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Yaw Rate Open
|
Yaw rate sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Deceleration Open
|
Acceleration sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Steering Open
|
Steering angle sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Stroke Open
|
Brake pedal stroke sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Stroke2 Open
|
Brake pedal stroke sensor 2 open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Accumulator Open
|
Accumulator pressure sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
HV Communication Open
|
Hybrid vehicle communication open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
FR Speed Sensor Voltage Open
|
Front speed sensor RH voltage open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
FL Speed Sensor Voltage Open
|
Front speed sensor LH voltage open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
RR Speed Sensor Voltage Open
|
Rear speed sensor RH voltage open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
RL Speed Sensor Voltage Open
|
Rear speed sensor LH voltage open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Yaw Rate Sensor Voltage Open
|
Yaw rate sensor voltage open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Detailed Freeze DTC
|
Information code (INF Code) for DTC
|
Min.: 0, Max.: 65535
|
-
|
Information code (INF Code) of DTC is displayed
|
Number of IG ON
|
Number of times power switch turned on (IG) after Freeze Frame Data stored
|
0 to 31
|
-
|
-
|
Buzzer
|
Meter buzzer
|
ON or OFF
|
ON: Buzzer on
OFF: Buzzer off
|
-
|
Stop Light SW
|
Stop light switch assembly
|
ON or OFF
|
ON: Brake pedal depressed
OFF: Brake pedal released
|
-
|
Parking Brake SW
|
Parking brake switch assembly
|
ON or OFF
|
ON: Parking brake applied
OFF: Parking brake released
|
-
|
TRC(TRAC)/VSC OFF SW
|
VSC OFF switch
|
ON or OFF
|
ON: Switch on
OFF: Switch off
|
-
|
Reservoir Warning SW
|
Brake fluid level warning switch
|
ON or OFF
|
ON: Reservoir level low
OFF: Reservoir level normal
|
-
|
Shift Lever Position
|
Shift position information
|
Fail, 1st, 2nd, 3rd, 4th, 5th, 6th/B, D/M, P,N or R
|
Actual shift position
|
-
|
Operated System
|
Operated system status
|
Non, ABS, VSC, TRAC, BA, HAB, Fail, PBA, PB, HA-CTRL, TSC, SCB or Sys
|
-
|
Non: No system activated
ABS: ABS activated
VSC: VSC activated
TRAC: TRAC activated
BA: BA activated
HAB: High power assist brake activated*
Fail: Fail-safe mode activated
PBA: PBA activated
PB: PB activated
HA-CTRL: Hill-start assist control activated
TSC: Trailer sway control activated*
SCB: Secondary collision brake activated
Sys: System prohibited
HINT:
*: Not supported
|
Stroke Sensor
|
Brake pedal stroke sensor
|
Min.: 0.00 V, Max.: 5.00 V
|
Brake pedal released: 0.65 to 1.35 V
|
Reading increases when brake pedal is depressed
|
Stroke Sensor Grade
|
Brake pedal stroke sensor change
|
Min.: -2560 mm/s, Max.: 2540 mm/s
|
Brake pedal released or depressed and held: 0 mm/s
|
Brake pedal is being moved: Changes in proportion to the operation speed of the brake pedal
|
Stroke Sensor2
|
Brake pedal stroke sensor 2
|
Min.: 0.00 V, Max.: 5.00 V
|
Brake pedal released: 3.65 to 4.35 V
|
Reading decreases when brake pedal is depressed
|
Yaw Rate Sensor
|
Yaw rate sensor
|
Min.: -128 degrees/s, Max.: 127 degrees/s
|
Vehicle stopped: 0 degrees/s
Turning right: -128 to 0 degrees/s
Turning left: 0 to 127 degrees/s
|
-
|
Lateral G
|
Lateral G
|
Min.: -25.10 m/s2, Max.: 24.90 m/s2
|
-
|
During turning: Changes in proportion with lateral acceleration
|
Forward and Rearward G
|
Forward and backward G
|
Min.: -25.10 m/s2, Max.: 24.90 m/s2
|
-
|
During acceleration/deceleration: Changes in proportion with acceleration
|
FR Wheel Speed
|
Front speed sensor RH
|
Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph)
|
Vehicle stopped: 0 km/h (0 mph)
|
When driving at constant speed: No large fluctuations
|
FL Wheel Speed
|
Front speed sensor LH
|
Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph)
|
Vehicle stopped: 0 km/h (0 mph)
|
When driving at constant speed: No large fluctuations
|
RR Wheel Speed
|
Rear speed sensor RH
|
Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph)
|
Vehicle stopped: 0 km/h (0 mph)
|
When driving at constant speed: No large fluctuations
|
RL Wheel Speed
|
Rear speed sensor LH
|
Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph)
|
Vehicle stopped: 0 km/h (0 mph)
|
When driving at constant speed: No large fluctuations
|
Vehicle Speed
|
Maximum wheel speed sensor
|
Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph)
|
Vehicle stopped: 0 km/h (0 mph)
|
When driving at constant speed: No large fluctuations
|
Vehicle Speed Grade
|
Vehicle acceleration
|
Min.: -25.10 m/s2, Max.: 24.90 m/s2
|
Vehicle stopped: 0 m/s2
|
During driving: Changes in proportion with vehicle acceleration/deceleration
|
Accelerator Opening Angle %
|
Percentage of accelerator pedal opening angle
|
Min.: 0.0%, Max.: 127.5%
|
Accelerator pedal released: 0.0%
|
During accelerator pedal operation: Changes in proportion with the pedal movement
|
ECB Motor Relay
|
Motor relay 1 operation request
|
ON or OFF
|
ON: Relay on
OFF: Relay off
|
ECB: Electronically Controlled Brake System
|
ECB Motor Relay2
|
Motor relay 2 operation request
|
ON or OFF
|
ON: Relay on
OFF: Relay off
|
ECB: Electronically Controlled Brake System
|
ECB Main Relay
|
Main relay operation request
|
ON or OFF
|
ON: Relay on
OFF: Relay off
|
ECB: Electronically Controlled Brake System
|
IG1 Voltage Value
|
IG1 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
IG2 Voltage Value
|
IG2 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
BS1 Voltage Value
|
BS1 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
BS2 Voltage Value
|
BS2 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
VM1 Voltage Value
|
VM1 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
VM2 Voltage Value
|
VM2 voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
Changes in proportion to auxiliary battery voltage
|
Motor Relay Voltage Value
|
Motor relay voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
-
|
-
|
FR Target Oil Pressure
|
Front wheel RH target oil pressure
|
Min.: 0.00 MPa, Max.: 20.00 MPa
|
-
|
Different according to target oil pressure of each wheel
|
FL Target Oil Pressure
|
Front wheel LH target oil pressure
|
Min.: 0.00 MPa, Max.: 20.00 MPa
|
-
|
Different according to target oil pressure of each wheel
|
RR Target Oil Pressure
|
Rear wheel RH target oil pressure
|
Min.: 0.00 MPa, Max.: 20.00 MPa
|
-
|
Different according to target oil pressure of each wheel
|
RL Target Oil Pressure
|
Rear wheel LH target oil pressure
|
Min.: 0.00 MPa, Max.: 20.00 MPa
|
-
|
Different according to target oil pressure of each wheel
|
Inspection Mode
|
Inspection mode
|
Other or Inspect
|
Other: Normal mode
Inspect: Inspection mode
|
-
|
Steering Angle Sensor
|
Steering angle sensor
|
Min.: - 3276.8 degrees, Max.: 3276.7 degrees
|
Turning left: Increases
Turning right: Decreases
|
-
|
VCM1 Voltage Value
|
VCM1 voltage value
|
Min.: 0.00 V, Max.: 10.00 V
|
6.29 to 7.64 V
|
-
|
VCM2 Voltage Value
|
VCM2 voltage value
|
Min.: 0.00 V, Max.: 10.00 V
|
6.29 to 7.64 V
|
-
|
TRAC/VSC Off Mode
|
TRAC/VSC off mode
|
Normal, TRC OFF, VSC Expert Mode or VSC OFF
|
Normal: Normal mode
TRC OFF: TRAC off mode
VSC Expert Mode: VSC expert mode
VSC OFF: VSC off mode
|
-
|
Brake Hold Control
|
Brake hold control status
|
OFF, Hold, Release or EPB
|
OFF: Brake hold control not operating
Hold: Brake hold operating during brake hold control
Release: Brake hold released during brake hold control
EPB: Electric parking brake operating during brake hold control
|
EPB: Electric Parking Brake System
|
Regulator Pressure Sensor Output Variant
|
Reaction force pressure sensor output variant
|
Min.: -30 MPa/s, Max.: 225 MPa/s
|
-
|
-
|
SLA Solenoid Current
|
Linear solenoid addition valve (SLA) current
|
Min.: 0.00 A, Max.: 1.50 A
|
Brake pedal released: 0.00 A
|
-
|
SLR Solenoid Current
|
Linear solenoid reduction valve (SLR) current
|
Min.: 0.00 A, Max.: 1.50 A
|
Brake pedal released: 0.00 A
|
-
|
Target Oil Pressure
|
Wheel target hydraulic pressure
|
Min.: 0.00 MPa, Max.: 20.00 MPa
|
-
|
Changes according to the target wheel cylinder hydraulic pressure
|
Voltage of Stroke Sensor
|
Voltage of brake pedal stroke sensor
|
Min.: -2.50 V, Max.: 2.49 V
|
-
|
-
|
Voltage of Stroke Sensor2
|
Voltage of brake pedal stroke sensor 2
|
Min.: -2.50 V, Max.: 2.49 V
|
-
|
-
|
IG Switch
|
Power switch on (IG) status
|
ON or OFF
|
-
|
-
|
Elapsed Time after Freeze Trigger
|
Elapsed time after storing Freeze Frame Data
|
Min.: 0 msec, Max.: 1020 msec
|
-
|
-
|
Reaction Force Pressure
|
Pressure value of stroke simulator
|
Min.: 0.00 MPa, Max.: 24.48 MPa
|
0.00 to 21.60 MPa
|
Brake pedal is being depressed: Changes in proportion to the depression force of the brake pedal
Brake pedal released: 0.00 MPa
|
Servo Pressure
|
Pressure value of servo
|
Min.: 0.00 MPa, Max.: 24.48 MPa
|
0.00 to 21.60 MPa
|
Brake pedal is being depressed: Changes in proportion to the depression force of the brake pedal
Brake pedal released: 0.00 to 2.10 MPa
|
Reaction Force Pressure Sensor Temperature
|
Reaction force pressure sensor temperature
|
Min.: -80°C (-112°F), Max.: 175°C (347°F)
|
-30°C (-22°F) to 100°C (212°F)
|
-
|
Servo Pressure Sensor Temperature
|
Servo pressure sensor temperature
|
Min.: -80°C (-112°F), Max.: 175°C (347°F)
|
-30°C (-22°F) to 100°C (212°F)
|
-
|
Accumulator Pressure Sensor Temperature
|
Accumulator pressure sensor temperature
|
Min.: -80°C (-112°F), Max.: 175°C (347°F)
|
-30°C (-22°F) to 100°C (212°F)
|
-
|
Accumulator Pressure
|
Accumulator pressure output value
|
Min.: 0.00 MPa, Max.: 24.48 MPa
|
0.00 to 21.60 MPa
|
When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator
|
MT Voltage Value (ABS)
|
ABS motor voltage value
|
Min.: 0.00 V, Max.: 20.00 V
|
ABS motor off: 0.00 V
ABS motor on: 11.00 to 14.00 V
|
-
|
VCSK Voltage Value
|
VCSK voltage value
|
Min.: 0.000 V, Max.: 5.500 V
|
4.800 to 5.200 V
|
-
|
ECB Solenoid (SGH)
|
Switching solenoid valve (SGH)
|
ON or OFF
|
ON: Solenoid on
OFF: Solenoid off
|
ECB: Electronically Controlled Brake System
|
ECB Solenoid (SSA)
|
Switching solenoid valve (SSA)
|
ON or OFF
|
ON: Solenoid on
OFF: Solenoid off
|
ECB: Electronically Controlled Brake System
|
Reaction Force Pressure Sensor Open
|
Reaction force pressure sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Servo Pressure Sensor Open
|
Servo pressure sensor open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|
Air Bag ECU Communication Open
|
Airbag ECU assembly communication open detection
|
Error or Normal
|
Error: Momentary interruption
Normal: Normal
|
-
|