Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001ANCK |
Model Year Start: 2019 |
Model: Avalon HV |
Prod Date Range: [04/2018 -
] |
Title: NETWORKING: CAN COMMUNICATION SYSTEM (for HV Model): Combination Meter ECU Communication Stop Mode; 2019 - 2022 MY Avalon HV [04/2018 - ] |
Combination Meter ECU Communication Stop Mode
|
DESCRIPTION
Detection Item
|
Symptom
|
Trouble Area
|
Combination Meter ECU Communication Stop Mode
|
Any of the following conditions are met:
|
-
Combination meter assembly main line or connector
-
Power source circuit of combination meter assembly
-
Combination meter assembly ground circuit
-
Combination meter assembly
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
HINT:
-
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
-
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
PROCEDURE
1.
|
CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY MAIN LINE)
|
(a) Disconnect the cable from the negative (-) auxiliary battery terminal.
(b) Disconnect the G16 combination meter assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
G16-32 (CANH) - G16-31 (CANL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
108 to 132 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Combination Meter Assembly)
|
|
|
NG |
|
REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (COMBINATION METER ASSEMBLY)
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
G16-2 (EP) - Body ground
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
G16-21 (ES) - Body ground
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Combination Meter Assembly)
|
|
|
(b) Reconnect the cable to the negative (-) auxiliary battery terminal.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
G16-39 (IG+) - Body ground
|
Power switch on (IG)
|
11 to 14 V
|
G16-40 (B) - Body ground
|
Power switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
|
|