                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001A3OO |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 - 08/2019] |  
                        | Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): No Warm Air Comes Out; 2019 MY Avalon HV [04/2018 - 08/2019] |  DESCRIPTIONIf cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. 
                     
                        
                        
                     
                     
                        
                           | Symptom | Factor |  
                           | 
                                 
                                    
No warm air comes out
                                          
                                             
(Blower control is normal)
Outlet air temperature does not increase
                                          
                                             
(Blower control is normal)
 | 
                                 
                                    
Engine coolant temperature (low)
Refrigerant volume (low)
No. 1 air conditioning radiator damper servo sub-assembly malfunction
Warm-up control
Blockage in heater radiator unit sub-assembly
Quick heater assembly malfunction
Heater radiator unit sub-assembly malfunction
Flow shutting valve (water by-pass hose assembly) malfunction
 |  PROCEDURE(a) Check for DTCs. Powertrain > Engine > Trouble CodesOK:  SFI system DTCs are not output. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 2.  | READ VALUE USING TECHSTREAM |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Engine / Data List. (e) Read the Data List according to the display on the Techstream. Powertrain > Engine > Data List
                     
                        
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |  
                           | Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. 
                                 HINT: 
                                    
After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
Check if the engine overheats if the value indicated is higher than 135°C (275°F).
 |  Powertrain > Engine > Data List
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Coolant Temperature |  OK:  After warming up the engine, the temperature value displayed is within the range specified in the normal condition column. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 3.  | PERFORM ACTIVE TEST USING TECHSTREAM |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Active Test. (e) Perform the Active Test according to the display on the Techstream. Body Electrical > Air Conditioner > Active Test
                     
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Control Range | Diagnostic Note |  
                           | Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128 Max.: 383 | Operates between 165 and 257 pulses |  
                           | Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128 Max.: 383 | Operates between 255 and 347 pulses |  Body Electrical > Air Conditioner > Active Test
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Air Mix Servo Targ Pulse(D) |  Body Electrical > Air Conditioner > Active Test
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Air Mix Servo Targ Pulse(P) |  OK:  Each damper servo motor operates. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 4.  | PERFORM ACTIVE TEST USING TECHSTREAM |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Active Test / Heater Active Level / Data List / Electric Heater Active Level. Body Electrical > Air Conditioner > Active Test
                     
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Control Range | Diagnostic Note |  
                           | Heater Active Level | Quick heater assembly | Min.: 0 Max.: 2 | - |  Body Electrical > Air Conditioner > Data List
                     
                        
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |  
                           | Electric Heater Active Level | Actual electric heater operation level | Min.: 0 Max.: 2 | Actual operation level of electric heater displayed | PTC heater circuit malfunction |  Body Electrical > Air Conditioner > Active Test
                     
                        
                     
                     
                        
                           | Active Test Display |  
                           | Heater Active Level |  
                     
                        
                     
                     
                        
                           | Data List Display |  
                           | Electric Heater Active Level |  (e) Check that the value of the Data List item Electric Heater Active Level changes in accordance with the set value of the Active Test item Heater Active Level. OK:  
                     
                        
                        
                     
                     
                        
                           | Techstream Operation | Data List (Electric Heater Active Level) |  
                           | 0 to 2 | 0 to 2 |  |