                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001A3ON |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 -                    
                                       ] |  
                        | Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): No Cool Air Comes Out; 2019 - 2022 MY Avalon HV [04/2018 -        ] |  DESCRIPTIONIf warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. 
                     
                        
                        
                     
                     
                        
                           | Symptom | Factor |  
                           | No cool air comes out 
                                 
                                    
(Blower control is normal)
 | 
                                 
                                    
Compressor with motor assembly malfunction
Refrigerant pressure is extremely high or low
Refrigerant volume (low)
Clogged cooler condenser assembly fins
Cooling fan system malfunction
Mechanical locking of damper and damper link
No. 1 cooler thermistor malfunction
High inlet air temperature
 |  PROCEDURE
                     
                        
                           | 1.  | CHECK SWITCH INDICATOR |  (a) Operate each switch on the air conditioning control panel (radio and display receiver assembly) and check that the switch indicators operate normally. OK:  All switch indicators operate normally. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 2.  | PERFORM ACTIVE TEST USING TECHSTREAM |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Active Test. (e) Perform the Active Test according to the display on the Techstream. Body Electrical > Air Conditioner > Active Test
                     
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Control Range | Diagnostic Note |  
                           | Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128 Max.: 383 | Operates between 165 and 257 pulses |  
                           | Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128 Max.: 383 | Operates between 255 and 347 pulses |  Body Electrical > Air Conditioner > Active Test
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Air Mix Servo Targ Pulse(D) |  Body Electrical > Air Conditioner > Active Test
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Air Mix Servo Targ Pulse(P) |  OK:  Each damper servo motor operates. |