Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): Front Window Fogging; 2019 - 2022 MY Avalon HV [04/2018 - ] |
DESCRIPTION
If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.
Symptom
|
Factor
|
Windshield frequently fogs up
|
-
Compressor with motor assembly malfunction
-
Refrigerant volume (low)
-
Cooler expansion valve (opened excessively)
-
No. 1 air conditioning radiator damper servo sub-assembly malfunction
-
Mechanical locking of damper and damper link
|
PROCEDURE
1.
|
PERFORM REFRIGERANT SHORTAGE CHECK
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
Item
|
Condition
|
A/C switch
|
On
|
Ambient temperature*
|
0 to 49°C (32 to 120°F)
|
Blower speed
|
HI
|
*: If the ambient temperature is not within the range shown, do not perform this check.
Result
|
Amount of Refrigerant
|
Refrigerant correct
|
Correct
|
Refrigerant shortage
|
Insufficient
|
OK:
"Refrigerant correct" is displayed on the Techstream.
OK
|
|
|
(a) Press the front defroster switch on the air conditioning control panel (radio and display receiver assembly).
OK:
The air outlet mode changes to DEF mode.
|