| S-FLOW Control Auto Function | Function to turn the S-FLOW control on automatically when the power switch is turned on (IG) | ON | 0:ON,1:OFF | Air conditioning amplifier assembly | 
                        
                           | Set Temperature Shift | Function to perform control with the shifted temperature versus the displayed temperature | Normal | 00001:-2C,00010:-1C,00100:Normal,01000:+1C,10000:+2C | Air conditioning amplifier assembly | 
                        
                           | Compressor Mode | Function to turn the A/C on automatically by pressing the AUTO switch when the blower is on and the A/C is off | Automatic | 0:Automatic,1:Manual | Air conditioning amplifier assembly | 
                        
                           | Air Inlet Mode | Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly*1 | Automatic | 0:Automatic,1:Manual | Air conditioning amplifier assembly | 
                        
                           | Foot/DEF Auto Mode | Function to change the air outlet mode to foot/defroster automatically when AUTO mode is on | ON | 0:ON,1:OFF | Air conditioning amplifier assembly | 
                        
                           | Foot/DEF Automatic Blow Up Function | Function to increase the blower level automatically when the defroster is on | ON | 0:ON,1:OFF | Air conditioning amplifier assembly | 
                        
                           | Ambient Temperature Shift | Function to display the shifted ambient temperature versus the actual ambient temperature | Normal | 0000001:-3C,0000010:-2C,0000100:-1C,0001000:Normal,0010000:+1C,0100000:+2C,1000000:+3C | Air conditioning amplifier assembly | 
                        
                           | ECO MODE Cancel | Function to disable the operation of the ECO switch assembly when set to OFF*2 | OFF | 0:OFF,1:ON | Air conditioning amplifier assembly | 
                        
                           | Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF | 0:OFF,1:ON | Air conditioning amplifier assembly | 
                        
                           | Refrigerant Shortage Check | Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON | ON | 0:ON,1:OFF | Air conditioning amplifier assembly | 
                        
                           | Fan speed increment control | Function to set the speed to reach the target blower fan speed when AUTO mode is on | Normal | 001:Slow,010:Normal,100:Fast | Air conditioning amplifier assembly | 
                        
                           | Outside Air Mode Auto Switch Function | Function to automatically change the air inlet to FRESH mode when the power switch is off for 60 seconds | ON | 0:ON,1:OFF | Air conditioning amplifier assembly |