                        | Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): B1423; Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure; 2019 - 2022 MY Avalon HV [04/2018 -        ] |  
                     
                        
                           | DTC | B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure |  DESCRIPTIONThis DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPaG (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor. 
                     
                        
                        
                        
                        
                        
                     
                     
                        
                           | DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |  
                           | B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure | 
                                 
                                    
Open or short in air conditioner pressure sensor circuit
Refrigerant pressure on high pressure side is extremely low (176 kPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPaG (30.8 kgf/cm2, 439 psi) or more)
 | 
                                 
                                    
Air conditioner pressure sensor
Harness or connector
Air conditioning amplifier assembly
Cooler expansion valve (blocked, stuck)
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt)
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)
Cooling fan system (cooler condenser assembly cannot be cooled down)
Air conditioning system (leaks, blocked)
Refrigerant volume (excessive, low)
 | - |  WIRING DIAGRAM  CAUTION / NOTICE / HINT
                     NOTICE: 
                        
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be stored if there is no refrigerant in the cycle.
Click here
                                 
                                    
                                       ![2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; HEATING / AIR CONDITIONING: REFRIGERANT: REPLACEMENT](/t3Portal/stylegraphics/info.gif) 
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
Click here
                                 
                                    
                                       ![2019 - 2022 MY Avalon HV [04/2018 -        ]; HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): B14B8; Refrigerant Shortage](/t3Portal/stylegraphics/info.gif)  HINT: Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again. PROCEDURE(a) Check for DTCs. Body Electrical > Air Conditioner > Trouble Codes
                     
                        
                           | Result | Proceed to |  
                           | B14B8 is not output | A |  
                           | B14B8 is output | B |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 2.  | COMPARE REFRIGERANT GAS PRESSURE VALUES SHOWN ON TECHSTREAM AND MANIFOLD GAUGE SET |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Data List. (e) Read the Data List according to the display on the Techstream. Body Electrical > Air Conditioner > Data List
                     
                        
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |  
                           | Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG Max.: 3294.37 kPaG | Actual refrigerant pressure displayed | 
                                 
                                    
Refrigerant line (gas leak etc.)
Air conditioner pressure sensor circuit malfunction
 |  Body Electrical > Air Conditioner > Data List
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Regulator Pressure Sensor |  (f) Install a manifold gauge set. Click here
                        
                           
                              ![2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; HEATING / AIR CONDITIONING: REFRIGERANT: ON-VEHICLE INSPECTION](/t3Portal/stylegraphics/info.gif)  (g) Compare the values displayed in the Data List and on the manifold gauge set. 
                     
                        
                           | Result | Proceed to |  
                           | Data List value and manifold gauge set value do not match and Data List value: 176 kPaG (1.8 kgf/cm2, 26 psi) or less | A |  
                           | Data List value and manifold gauge set value do not match and Data List value: 3025 kPaG (30.8 kgf/cm2, 439 psi) or more | B |  
                           | Data List value matches manifold gauge set value | C |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 3.  | READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR) |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Data List. (e) Read the Data List according to the display on the Techstream. Body Electrical > Air Conditioner > Data List
                     
                        
                        
                        
                        
                        
                     
                     
                        
                           | Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |  
                           | Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG Max.: 3294.37 kPaG | Actual refrigerant pressure displayed | 
                                 
                                    
Refrigerant line (gas leak etc.)
Air conditioner pressure sensor circuit malfunction
 |  Body Electrical > Air Conditioner > Data List
                     
                        
                     
                     
                        
                           | Tester Display |  
                           | Regulator Pressure Sensor |  OK:  Disconnecting the A15 connector of the air conditioner pressure sensor causes the Data List value to change. 
                     
                        
                           | Result | Proceed to |  
                           | Regulator pressure sensor value changes | A |  
                           | Regulator pressure sensor value does not change | B |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 4.  | CHECK TERMINAL VOLTAGE (AIR CONDITIONER PRESSURE SENSOR) |  
                     
                        
                           | (a) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A15-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |  | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |  |  |  
                     
                        | 
                              
                                 | NG |  
                                 |   |  |  
                     
                        
                           | 5.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-3 (+) - G36-6 (S5-3) | Always | Below 1 Ω |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        
                           | 6.  | CHECK TERMINAL VOLTAGE (AIR CONDITIONING AMPLIFIER ASSEMBLY) |  
                     
                        
                           | (a) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A15-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |  | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |  |  |  
                     
                        | 
                              
                                 | NG |  
                                 |   |  |  
                     
                        
                           | 7.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-2 (PR) or G36-24 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        
                           | 8.  | CHECK HARNESS AND CONNECTOR |  (a) Disconnect the A15 air conditioner pressure sensor connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-1 (-) - Body ground | Always | Below 1 Ω |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 9.  | CHECK TERMINAL VOLTAGE |  
                     
                        
                           | (a) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A15-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |  | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |  |  |  
                     
                        
                           | Result | Proceed to |  
                           | 5.25 V or higher | A |  
                           | 3.0 to 5.25 V | B |  
                           | Below 3.0 V | C |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 10.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-2 (PR) or G36-24 (PRE) - Other terminals | Always | 10 kΩ or higher |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        
                           | 11.  | CHECK INTERNAL CIRCUIT RESISTANCE (AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-3 (+) - A15-2 (PR) | Power switch off | 180 to 220 kΩ |  HINT: After turning the power switch off, wait at least 30 seconds before performing the measurement. 
                     
                        | 
                              
                                 | NG |  
                                 |   |  |  
                     
                        
                           | 12.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-2 (PR) or G36-24 (PRE) - A15-3 (+) or G36-6 (S5-3) | Always | 10 kΩ or higher |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        
                           | 13.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-2 (PR) - G36-24 (PRE) | Always | Below 1 Ω |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        
                           | 14.  | CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |  (a) Disconnect the G36 air conditioning amplifier assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A15-1 (-) - G36-3 (SG-4) | Always | Below 1 Ω |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  |