                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001A0HV |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 - 08/2020] |  
                        | Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P034000,P034031; Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; 2019 - 2020 MY Avalon HV [04/2018 - 08/2020] |  
                     
                        
                           | DTC | P034000 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |  
                     
                        
                           | DTC | P034031 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |  DESCRIPTIONIf the cam position signal pulse sent from the ECM via a direct line is abnormal, the motor generator control ECU (MG ECU) (built into the inverter with converter assembly) stores DTC P034000 or P034031. 
                     
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |  
                           | P034000 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor | GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running* (1 trip detection logic) | 
                                 
                                    
SFI system
Inverter with converter assembly
ECM
Wire harness or connector
 | Does not come on | Master Warning Light: Comes on |  
                           | P034031 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal | GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running* (1 trip detection logic) | 
                                 
                                    
SFI system
Inverter with converter assembly
ECM
Wire harness or connector
 | Does not come on | Master Warning Light: Comes on |  HINT: *: When this DTC is stored, vibration may occur when the engine is stopped. Related Data List
                     
                        
                        
                     
                     
                        
                           | DTC No. | Data List |  
                           | P034000 P034031 | 
                                 
                                    
Crank Position (Hybrid control system)
Engine Speed
 |  CONFIRMATION DRIVING PATTERNHINT: After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): UTILITY](/t3Portal/stylegraphics/info.gif)  
                     
                        
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the Techstream on.
Turn the power switch on (READY).
With the vehicle stopped, move the shift lever to P.
Depress the accelerator pedal to start the engine.
Depress the accelerator pedal and maintain the engine speed at 1000 rpm or more for 5 seconds or more.
NOTICE: As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
                              HINT: 
                                 
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
 WIRING DIAGRAM  CAUTION / NOTICE / HINT
                     CAUTION:   NOTICE: After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Click here
                        
                           
                              ![2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION](/t3Portal/stylegraphics/info.gif)  PROCEDURE
                     
                        
                           | 1.  | CHECK DTC OUTPUT (ENGINE) |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Enter the following menus: Powertrain / Engine / Trouble Codes. (d) Check for DTCs. Powertrain > Engine > Trouble Codes
                     
                        
                           | Result | Proceed to |  
                           | SFI system DTCs are not output. | A |  
                           | Any of the following DTCs are also output. | B |  
                     
                        
                        
                     
                     
                        
                           | Relevant DTC |  
                           | P034011 | Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Ground |  
                           | P034015 | Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Battery or Open |  
                           | P03402A | Camshaft Position Sensor "A" Bank 1 or Single Sensor Signal Stuck in Range |  
                           | P034031 | Camshaft Position Sensor "A" Bank 1 or Single Sensor No Signal |  (e) Turn the power switch off. 
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 2.  | CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL) |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes. (d) Check for DTCs. Powertrain > Motor Generator > Trouble Codes
                     
                        
                           | Result | Proceed to |  
                           | None of the following DTCs are output. | A |  
                           | Any of the following DTCs are also output. | B |  
                     
                        
                        
                     
                     
                        
                           | Relevant DTC |  
                           | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |  
                           | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |  
                           | P0A1B1F | Generator Control Module Circuit Intermittent |  
                           | P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |  
                           | P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |  
                           | P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure |  
                           | P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |  
                           | P313487 | Communication Error from Drive Motor "A" to Generator Missing Message |  
                           | P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |  
                           | P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid |  HINT: P034000 or P034031 may be stored due to a malfunction which also causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output. (e) Turn the power switch off. 
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 3.  | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |  Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P033500,P033531; Crankshaft Position Sensor "A"+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | Result | Proceed to |  
                           | OK | A |  
                           | NG (The connector is not connected securely.) | B |  
                           | NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |  
                     
                        
                           | B |   | CONNECT SECURELY |  
                     
                        
                           | C |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 4.  | CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR) |  Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P033500,P033531; Crankshaft Position Sensor "A"+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | NG |   | CONNECT SECURELY |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 5.  | CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM) |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Disconnect the A42 inverter with converter assembly connector. (c) Disconnect the A19 ECM connector. (d) Connect the cable to the negative (-) auxiliary battery terminal. (e) Turn the power switch on (IG). 
                     
                        
                           | (f) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A42-10 (GI) - Body ground | Power switch on (IG) | Below 1 V |  NOTICE: Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Front view of wire harness connector (to Inverter with Converter Assembly) |  
                                                | *b | Front view of wire harness connector (to ECM) |  |  |  (g) Turn the power switch off. (h) Measure the resistance according to the value(s) in the table below. Standard Resistance (Check for Open):  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A42-10 (GI) - A19-24 (G2O) | Power switch off | Below 1 Ω |  Standard Resistance (Check for Short):  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A42-10 (GI) or A19-24 (G2O) - Body ground and other terminals | Power switch off | 10 kΩ or higher |  (i) Disconnect the cable from the negative (-) auxiliary battery terminal. (j) Reconnect the A19 ECM connector. (k) Reconnect the A42 inverter with converter assembly connector. 
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  (a) Disconnect the A19 ECM connector. (b) Measure the resistance according to the value(s) in the table below.   
                     
                        
                        
                        
                        
                     
                     
                        
                           | *a | Component without harness connected (ECM) | - | - |  Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A19-24 (G2O) - A19-10 (E1) | Power switch off | 10 kΩ or higher |  (c) Reconnect the A19 ECM connector. |