| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety μC Failure | 
                        
                           | P0A1A49 | Generator Control Module Internal Electronic Failure | 
                        
                           | P0A1B1F | Generator Control Module Circuit Intermittent | 
                        
                           | P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | 
                        
                           | P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | 
                        
                           | P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | 
                        
                           | P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | 
                        
                           | P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | 
                        
                           | P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | 
                        
                           | P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | 
                        
                           | P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | 
                        
                           | P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | 
                        
                           | P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | 
                        
                           | Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | 
                        
                           | Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | 
                        
                           | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | 
                        
                           | Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message | 
                        
                           | Hybrid control system | P312387 | Lost Communication with Missing Message | 
                        
                           | Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | 
                        
                           | P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | 
                        
                           | P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | 
                        
                           | P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | 
                        
                           | P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | 
                        
                           | P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | 
                        
                           | P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | 
                        
                           | P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | 
                        
                           | P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | 
                        
                           | P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | 
                        
                           | P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | 
                        
                           | P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | 
                        
                           | P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | 
                        
                           | P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | 
                        
                           | P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | 
                        
                           | P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | 
                        
                           | P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | 
                        
                           | P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | 
                        
                           | P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | 
                        
                           | P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | 
                        
                           | P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | 
                        
                           | P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | 
                        
                           | P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | 
                        
                           | P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | 
                        
                           | P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | 
                        
                           | P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | 
                        
                           | P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | 
                        
                           | P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | 
                        
                           | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | 
                        
                           | P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | 
                        
                           | P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | 
                        
                           | P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | 
                        
                           | P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | 
                        
                           | P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | 
                        
                           | P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | 
                        
                           | P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | 
                        
                           | P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | 
                        
                           | P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | 
                        
                           | P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | 
                        
                           | P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | 
                        
                           | P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | 
                        
                           | P1CAC49 | Generator Position Sensor Internal Electronic Failure | 
                        
                           | P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | 
                        
                           | P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | 
                        
                           | P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | 
                        
                           | P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | 
                        
                           | Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | 
                        
                           | P0D2D1C | Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range | 
                        
                           | P0E311C | Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range | 
                        
                           | System malfunction | Motor generator control system | P0A9000 | Drive Motor "A" Performance | 
                        
                           | P0A9200 | Hybrid Generator Performance | 
                        
                           | P0BFF1D | Drive Motor "A" Circuit Current Out of Range | 
                        
                           | P0C1900 | Drive Motor "A" Execution Torque Performance | 
                        
                           | P0CA300 | DC/DC Converter Step Up Voltage Performance | 
                        
                           | P0E7100 | Generator Execution Torque Performance | 
                        
                           | P1CA51D | Hybrid Generator Circuit Current Out of Range | 
                        
                           | P314F1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent | 
                        
                           | P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range | 
                        
                           | Hybrid control system | P0A9300 | Inverter "A" Cooling System | 
                        
                           | P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure | 
                        
                           | P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | 
                        
                           | P314A31 | Motor Electronics Coolant Pump "A" No Signal |