Last Modified: 08-21-2023 |
6.11:8.1.0 |
Doc ID: RM100000001A0GM |
Model Year Start: 2019 |
Model: Avalon HV |
Prod Date Range: [04/2018 - 08/2020] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P0A1112,P0A1114; DC/DC Converter Enable Circuit Short to Battery; 2019 - 2020 MY Avalon HV [04/2018 - 08/2020] |
DTC
|
P0A1112
|
DC/DC Converter Enable Circuit Short to Battery
|
DTC
|
P0A1114
|
DC/DC Converter Enable Circuit Short to Ground or Open
|
DESCRIPTION
Refer to the description for DTC P1CCC96.
Click here
The motor generator control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal (below 11 V) condition of the 12 V charging system from the DC/DC converter via the NODD signal line.
If the vehicle is being driven with an inoperative DC/DC converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the motor generator control ECU monitors the operation of the DC/DC converter and alerts the driver if it detects a malfunction.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A1112
|
DC/DC Converter Enable Circuit Short to Battery
|
Short to +B detected in DC/DC converter NODD signal line
(1 trip detection logic)
|
-
Wire harness or connector
-
Inverter with converter assembly
|
Does not come on
|
Master Warning Light:
Comes on
|
P0A1114
|
DC/DC Converter Enable Circuit Short to Ground or Open
|
Open or short to ground detected in DC/DC converter NODD signal line
(1 trip detection logic)
|
-
Wire harness or connector
-
Inverter with converter assembly
|
Does not come on
|
Master Warning Light:
Comes on
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 10 seconds or more.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
HINT:
If the NODD signal line is open, DC/DC converter control will be prohibited and the auxiliary battery voltage will be approximately 12 V or less.
Click here
PROCEDURE
1.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
A
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the A42 inverter with converter assembly connector.
(c) Remove the IGCT relay from the instrument panel relay block.
(d) Measure the resistance according to the value(s) in the table below.
*1
|
Instrument Panel Relay Block
|
*2
|
IGCT Relay
|
*a
|
Front view of wire harness connector
(to Inverter with Converter Assembly)
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A42-12 (IGCT) - 5 (IGCT relay)
|
Power switch off
|
Below 1 Ω
|
(e) Install the IGCT relay.
(f) Reconnect the A42 inverter with converter assembly connector.
NG |
|