                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001A0E8 |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 - 08/2020] |  
                        | Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P321E9F; Motor/Generator Shutdown Signal Stuck Off; 2019 - 2020 MY Avalon HV [04/2018 - 08/2020] |  
                     
                        
                           | DTC | P321E9F | Motor/Generator Shutdown Signal Stuck Off |  DTC SUMMARYMALFUNCTION DESCRIPTION The hybrid vehicle control ECU detects malfunctions which prevent the inverter with converter assembly emergency shutdown circuit (HSDN) from shutting down the hybrid control system. Detection is performed when the power switch is turned on (IG) and during the shutdown sequence when the power switch is turned off. The cause of this malfunction may be one of the following: 
                     Hybrid vehicle control ECU and inverter with converter assembly shutdown circuit malfunction
                        
Hybrid vehicle control ECU malfunction
Connector or wire harness malfunction (between hybrid vehicle control ECU and inverter with converter assembly) malfunction
Inverter with converter assembly malfunction
 DESCRIPTIONThe hybrid vehicle control ECU sends a block signal to the motor generator control ECU (MG ECU) to shutdown the power supply to the motor. When the system is not in the on (READY) state, it sends an HSDN (MG shutdown signal) signal from the hybrid vehicle control ECU to the motor generator control ECU (MG ECU) to check the function of the HV gate block. When a malfunction is detected in the HV gate block function, DTCs are stored. 
                     
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |  
                           | P321E9F | Motor/Generator Shutdown Signal Stuck Off | When the HV gate block function check is performed (when the power switch is turned from on (READY) to off), the inverter voltage (VH) drops and current flows in the inverter. (1 trip detection logic) | 
                                 
                                    
Wire harness or connector
Hybrid vehicle control ECU
Inverter with converter assembly
 | Does not come on | Master Warning Light: Comes on |  Related Data List
                     
                        
                        
                     
                     
                        
                           | DTC No. | Data List |  
                           | P321E9F | 
                                 
                                    
VH-Voltage after Boosting
Ready Signal
Inverter Emergency Shutdown (Main CPU)
Inverter Emergency Shutdown (Sub CPU)
 |  CONFIRMATION DRIVING PATTERNHINT: After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): UTILITY](/t3Portal/stylegraphics/info.gif)  
                     
                        
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the Techstream on.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
                              HINT: 
                                 
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
 WIRING DIAGRAMRefer to the wiring diagram for the shut down signal circuit. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): Shut Down Signal Circuit+](/t3Portal/stylegraphics/info.gif)  CAUTION / NOTICE / HINTNOTICE: After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Click here
                        
                           
                              ![2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION](/t3Portal/stylegraphics/info.gif)  PROCEDURE
                     
                        
                           | 1.  | CHECK DTC OUTPUT (HYBRID CONTROL) |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. (d) Check for DTCs. Powertrain > Hybrid Control > Trouble Codes
                     
                        
                           | Result | Proceed to |  
                           | P321E9F only is output, or DTCs except the ones in the table below are also output | A |  
                           | Any of the following DTCs are also output | B |  
                     
                        
                        
                        
                     
                     
                        
                           | Malfunction Content | Relevant DTC |  
                           | Sensor and actuator circuit malfunction | P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |  
                           | P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |  
                     HINT: 
                        
P321E9F may be output as a result of the malfunction indicated by the DTCs above.
                              
                                 
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
 (e) Turn the power switch off. 
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 2.  | CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |  Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P056014; System Voltage (BATT) Circuit Short to Ground or Open+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | NG |   | CONNECT SECURELY |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 3.  | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |  Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P033500,P033531; Crankshaft Position Sensor "A"+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | Result | Proceed to |  
                           | OK | A |  
                           | NG (The connector is not connected securely.) | B |  
                           | NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |  
                     
                        
                           | B |   | CONNECT SECURELY |  
                     
                        
                           | C |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 4.  | CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - HYBRID VEHICLE CONTROL ECU) |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Disconnect the A42 inverter with converter assembly connector. (c) Disconnect the A24 hybrid vehicle control ECU connector. 
                     
                        
                           | (d) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A42-22 (HSDN) - A24-12 (HSDN) | Power switch off | Below 1 Ω |  
                                       | A42-22 (HSDN) or A24-12 (HSDN) - Body ground and other terminals | Power switch off | 10 kΩ or higher |  | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Front view of wire harness connector (to Inverter with Converter Assembly) |  
                                                | *b | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |  |  |  (e) Reconnect the A24 hybrid vehicle control ECU connector. (f) Reconnect the A42 inverter with converter assembly connector. 
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 5.  | CHECK INVERTER WITH CONVERTER ASSEMBLY |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Disconnect the A42 inverter with converter assembly connector. 
                     
                        
                           | (c) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | A42-22 (HSDN) - A42-24 (GND1) | Power switch off | 2.65 to 3.55 kΩ |  NOTICE: Be sure not to damage or deform the terminal being inspected. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Component without harness connected (Inverter with Converter Assembly) |  |  |  (d) Reconnect the A42 inverter with converter assembly connector. |