                        | Last Modified: 08-21-2023 | 6.11:8.1.0 | Doc ID: RM100000001A0DY |  
                        | Model Year Start: 2019 | Model: Avalon HV | Prod Date Range: [04/2018 - 08/2020] |  
                        | Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P1C8149,P1C8249; High Voltage Power Resource Circuit Consumption Circuit Short; 2019 - 2020 MY Avalon HV [04/2018 - 08/2020] |  
                     
                        
                           | DTC | P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |  
                     
                        
                           | DTC | P1C8249 | High Voltage Power Resource Circuit Over Loading |  DTC SUMMARYMALFUNCTION DESCRIPTION The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and inverter with converter assembly and detects a short circuit malfunction or high-voltage system operation malfunction. The cause of this malfunction may be one of the following: 
                     Battery current sensor (IB) circuit malfunction
                        
Battery current sensor (IB) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
 
                     High voltage system malfunction
                        
HV battery malfunction
HV battery junction block assembly malfunction
Inverter with converter assembly malfunction
Air conditioner system malfunction
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
 
                     Low-voltage circuit (12 V) malfunction
                        
Hybrid vehicle control ECU malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
 INSPECTION DESCRIPTION   
                     
                        
                        
                        
                        
                     
                     
                        
                           | System Diagram Location | Inspection Content | Reason | Inspection Step |  
                           | *a | Check high-voltage wiring connection condition of the air conditioner compressor with motor assembly | Check for short circuit | 2, 4 |  
                           | *b | Check the high voltage cables between the HV battery junction block assembly and inverter with converter assembly. | Check for short circuit | 3, 5 |  DESCRIPTIONRefer to the description for DTC P0AE411. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P0AE411; Hybrid/EV Battery Precharge Contactor Circuit Short to Ground+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |  
                           | P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | High-voltage circuit malfunctions between the HV battery and inverter with converter assembly. Excessive overcurrent equal to a short occurs during precharge (time from when SMRP turns on until SMRG turns on). (1 trip detection logic) | 
                                 
                                    
Air conditioning wire
Compressor with motor assembly
Inverter with converter assembly
HV battery junction block assembly
HV floor under wire
 | Does not come on | Master Warning Light: Comes on |  
                           | P1C8249 | High Voltage Power Resource Circuit Over Loading | High-voltage circuit malfunctions between the HV battery and inverter with converter assembly. Small battery overcurrent occurs during precharge (time from when SMRP turns on until SMRG turns on) and current continues to flow after precharge. (1 trip detection logic) | 
                                 
                                    
Air conditioning wire
Compressor with motor assembly
Inverter with converter assembly
HV battery junction block assembly
HV floor under wire
 | Does not come on | Master Warning Light: Comes on |  Related Data List
                     
                        
                        
                     
                     
                        
                           | DTC No. | Data List |  
                           | P1C8149 | 
                                 
                                    
Hybrid Battery Voltage
Hybrid Battery Current
VL-Voltage before Boosting
VH-Voltage after Boosting
 |  
                           | P1C8249 |  CONFIRMATION DRIVING PATTERNHINT: After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): UTILITY](/t3Portal/stylegraphics/info.gif)  
                     
                        
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the Techstream on.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
                              HINT: 
                                 
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
 WIRING DIAGRAMRefer to the wiring diagram for DTC P0AA649. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P0AA649,...,P1C7F49; Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure+](/t3Portal/stylegraphics/info.gif)  CAUTION / NOTICE / HINTNOTICE: After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Click here
                        
                           
                              ![2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION](/t3Portal/stylegraphics/info.gif)  PROCEDURE
                     
                        
                           | 1.  | CHECK DTC OUTPUT (HYBRID CONTROL, MOTOR GENERATOR) |  (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes. (d) Check for DTCs. Powertrain > Hybrid Control > Trouble CodesPowertrain > Motor Generator > Trouble Codes
                     
                        
                           | Result | Proceed to |  
                           | P1C8149 or P1C8249 only is output, or DTCs except the ones in the tables below are also output. | A |  
                           | DTCs of hybrid control system in the tables below are output. | B |  
                           | DTCs of motor generator control system in the tables below are output. | C |  
                     
                        
                        
                        
                        
                     
                     
                        
                           | Malfunction Content | System | Relevant DTC |  
                           | Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |  
                           | P0AFC96 | Hybrid/EV Battery Sensor Module Component Internal Failure |  
                           | P0AFC00 | Hybrid/EV Battery Sensor Module |  
                           | Power source circuit malfunction | Hybrid control system | P0AFC16 | Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |  
                           | Communication system malfunction | Hybrid control system | U029A87 | Lost Communication with Hybrid/EV Battery Sensor Module Missing Message |  
                           | Sensor and actuator circuit malfunction | Hybrid control system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground |  
                           | P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open |  
                           | P0B3B14 | Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open |  
                           | P0B4014 | Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open |  
                           | P0B4514 | Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open |  
                           | P0B4A14 | Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open |  
                           | P0B4F14 | Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open |  
                           | P0B5414 | Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open |  
                           | P0B5914 | Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open |  
                           | P0B5E14 | Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open |  
                           | P0B6314 | Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open |  
                           | P0B6814 | Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open |  
                           | P0B6D14 | Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open |  
                           | P0B7214 | Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open |  
                           | P308A13 | Hybrid/EV Battery Voltage Sensor All Circuit Open |  
                           | P0AFC62 | Hybrid/EV Battery Sensor Module Signal Compare Failure |  
                           | P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |  
                           | P308A12 | Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery |  
                           | P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |  
                           | P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure |  
                           | P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range |  
                           | Motor generator control system | P0A1114 | DC/DC Converter Enable Circuit Short to Ground or Open |  
                           | P0A1112 | DC/DC Converter Enable Circuit Short to Battery |  
                           | P1CCC96 | DC/DC Converter Enable Component Internal Failure |  
                           | System malfunction | Motor generator control system | P0D3319 | DC/DC Converter Circuit Current Above Threshold |  
                     HINT: 
                        
P1C8149 or P1C8249 may be output as a result of the malfunction indicated by the DTCs above.
                              
                                 
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
 (e) Turn the power switch off. 
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 2.  | CHECK COMPRESSOR WITH MOTOR ASSEMBLY |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. 
                     
                        
                           | (b) Disconnect the air conditioning wire connector from the inverter with converter assembly. |  |  
                     
                        
                           | (c) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection (Tester Probe Polarity) | Condition | Specified Condition |  
                                       | T2-2 (ACPE) (Negative (-) probe) - T2-1 (ACPB) (Positive (+) probe) | Power switch off | 100 kΩ or higher |  
                                 NOTICE: 
                                    
Do not use a megohmmeter.
Read the resistance after the value has stabilized.
Be sure to inspect with connecting the tester probes to the tips of the terminal.
 | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | Air conditioning wire (Inverter with Converter Assembly Side) |  
                                                | *b | Tip of Terminal |  |  |  (d) Reconnect the air conditioning wire connector. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 3.  | CHECK HV FLOOR UNDER WIRE |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. 
                     
                        
                           | (b) Disconnect the HV floor under wire connector from the inverter with converter assembly. |  |  
                     
                        
                           | (c) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | S1-1 (CBI) - S1-2 (CEI) | Power switch off | 10 kΩ or higher |  NOTICE: Be sure not to damage or deform the terminal being inspected. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | HV Floor Under Wire (Inverter with Converter Assembly Side) |  |  |  (d) Reconnect the HV floor under wire connector. 
                     
                        
                           | 4.  | CHECK HV AIR CONDITIONING WIRE |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. 
                     
                        
                           | (b) Disconnect the HV air conditioning wire connector from the inverter with converter assembly. |  |  
                     
                        
                           | (c) Disconnect the HV air conditioning wire from the compressor with motor assembly. Click here
                                    
                                       
                                          ![2019 - 2021 MY Avalon HV [04/2018 - 08/2021]; HEATING / AIR CONDITIONING: COMPRESSOR (for A25A-FXS): REMOVAL+](/t3Portal/stylegraphics/info.gif)  |  |  
                     
                        
                           | (d) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | T2-2 (ACPE) - T2-1 (ACPB) | Power switch off | 10 kΩ or higher |  NOTICE: Be sure to inspect with connecting the tester probes to the tips of the terminal. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | HV air conditioning wire (Inverter with Converter Assembly Side) |  
                                                | *b | Tip of Terminal |  |  |  (e) Reconnect the HV air conditioning wire connector to the inverter with converter assembly. (f) Reconnect the HV air conditioning wire to the compressor with motor assembly. 
                     
                        
                           | NG |   | REPLACE HV AIR CONDITIONING WIRE |  
                     
                        
                           | 5.  | CHECK HV FLOOR UNDER WIRE |  CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Remove the No. 1 HV battery cover panel RH. Click here
                        
                           
                              ![2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HV BATTERY (for NICKEL METAL HYDRIDE BATTERY): REMOVAL+](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | (c) Disconnect the HV floor under wire connectors from the HV battery junction block assembly. |  |  
                     
                        
                           | (d) Disconnect the HV floor under wire connector from the inverter with converter assembly. |  |  
                     
                        
                           | (e) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                                 
                                 
                                 
                                 
                                    
                                       | Tester Connection | Condition | Specified Condition |  
                                       | S1-1 (CBI) - S1-2 (CEI) | Power switch off | 10 kΩ or higher |  NOTICE: Be sure not to damage or deform the terminal being inspected. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | HV Floor Under Wire (Inverter with Converter Assembly Side) |  |  |  (f) Reconnect the HV floor under wire connector to the inverter with converter assembly. (g) Reconnect the HV floor under wire connectors to the HV battery junction block assembly. (h) Install the No. 1 HV battery cover panel RH. |