| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | 
                        
                           | P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | 
                        
                           | P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | 
                        
                           | P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | 
                        
                           | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | 
                        
                           | P1C9E9F | Hybrid/EV System Reset Stuck Off | 
                        
                           | Motor generator control system | P0A1B1F | Generator Control Module Circuit Intermittent | 
                        
                           | P0A1A47 | Generator Control Module Watchdog / Safety μC Failure | 
                        
                           | P0A1A49 | Generator Control Module Internal Electronic Failure | 
                        
                           | P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | 
                        
                           | P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | 
                        
                           | P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | 
                        
                           | P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | 
                        
                           | P1CAC49 | Generator Position Sensor Internal Electronic Failure | 
                        
                           | P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | 
                        
                           | P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | 
                        
                           | P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | 
                        
                           | P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | 
                        
                           | P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | 
                        
                           | P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | 
                        
                           | Power source circuit malfunction | Motor generator control system | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | 
                        
                           | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | 
                        
                           | Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | 
                        
                           | Sensor and actuator circuit malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | 
                        
                           | P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | 
                        
                           | P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | 
                        
                           | P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | 
                        
                           | P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | 
                        
                           | P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | 
                        
                           | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | 
                        
                           | P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | 
                        
                           | P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | 
                        
                           | P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | 
                        
                           | P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | 
                        
                           | P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | 
                        
                           | P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | 
                        
                           | P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | 
                        
                           | P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | 
                        
                           | P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | 
                        
                           | P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | 
                        
                           | P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | 
                        
                           | P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | 
                        
                           | P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | 
                        
                           | P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | 
                        
                           | P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | 
                        
                           | System malfunction | Hybrid control system | P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | 
                        
                           | P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | 
                        
                           | Motor generator control system | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | 
                        
                           | P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | 
                        
                           | P1CB69E | Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On |