Last Modified: 08-21-2023 6.11:8.1.0 Doc ID: RM100000001A0D7
Model Year Start: 2019 Model: Avalon HV Prod Date Range: [04/2018 - 08/2020]
Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): Inverter Low-voltage Circuit; 2019 - 2020 MY Avalon HV [04/2018 - 08/2020]

Inverter Low-voltage Circuit

DESCRIPTION

The cause of the malfunction may be the low-voltage circuit.

Check whether there is an open circuit in the inverter +B low-voltage power source system or a problem in the communication between the hybrid vehicle control ECU and inverter.

Related Parts Check

Area

Inspection

Inverter +B low-voltage power source system check

Check for inverter overcurrent malfunction.

Communication malfunction between hybrid vehicle control ECU and MG-ECU inside inverter with converter assembly

Check for inverter overcurrent malfunction due to communication malfunction.

Check for short to ground in inverter +B low-voltage power source system

-

WIRING DIAGRAM

CAUTION / NOTICE / HINT

This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.

If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    *a

    Without waiting for 10 minutes

    Click here 2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): PRECAUTION

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here 2019 - 2022 MY Avalon Avalon HV [04/2018 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION

PROCEDURE

1.

CHECK FUSE (PCU)

(a) Remove the PCU fuse from the No. 4 relay block.

*1

No. 4 Relay Block

*2

PCU Fuse

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

PCU fuse

Always

Below 1 Ω

(c) Install the PCU fuse.

NG

GO TO STEP 5

OK

2.

CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

CAUTION:

Be sure to wear insulated gloves.

(a) Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

(b) Disconnect the A42 inverter with converter assembly connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A42-24 (GND1) - Body ground

Power switch off

Below 1 Ω

A42-23 (GND2) - Body ground

Power switch off

Below 1 Ω

*a

Front view of wire harness connector

(to Inverter with Converter Assembly)

(d) Connect the cable to the negative (-) auxiliary battery terminal.

(e) Turn the power switch on (IG).

(f) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Condition

Specified Condition

A42-6 (+B) - Body ground

Power switch on (IG)

Same as auxiliary battery voltage

A42-5 (+B2) - Body ground

Power switch on (IG)

Same as auxiliary battery voltage

NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

(g) Turn the power switch off.

(h) Disconnect the cable from the negative (-) auxiliary battery terminal and wait for 2 minutes or more.

(i) Reconnect the A42 inverter with converter assembly connector.

NG

REPAIR OR REPLACE POWER SOURCE CIRCUIT

OK

3.

CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:

Be sure to wear insulated gloves.

(a) Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

(b) Disconnect the A42 inverter with converter assembly connector.

(c) Disconnect the A24 hybrid vehicle control ECU connector.

(d) Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):

Tester Connection

Condition

Specified Condition

A42-20 (HMCH) - A24-31 (HMCH)

Power switch off

Below 1 Ω

A42-19 (HMCL) - A24-30 (HMCL)

Power switch off

Below 1 Ω

Standard Resistance (Check for Short):

Tester Connection

Condition

Specified Condition

A42-20 (HMCH) or A24-31 (HMCH) - Body ground and other terminals

Power switch off

10 kΩ or higher

A42-19 (HMCL) or A24-30 (HMCL) - Body ground and other terminals

Power switch off

10 kΩ or higher

*a

Front view of wire harness connector

(to Inverter with Converter Assembly)

*b

Rear view of wire harness connector

(to Hybrid Vehicle Control ECU)

(e) Connect the cable to the negative (-) auxiliary battery terminal.

(f) Turn the power switch on (IG).

(g) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Condition

Specified Condition

A42-20 (HMCH) or A24-31 (HMCH) - Body ground and other terminals

Power switch on (IG)

Below 1 V

A42-19 (HMCL) or A24-30 (HMCL) - Body ground and other terminals

Power switch on (IG)

Below 1 V

NOTICE:

Turning the power switch on (IG) with the hybrid vehicle control ECU and inverter with converter assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

(h) Turn the power switch off.

(i) Disconnect the cable from the negative (-) auxiliary battery terminal and wait for 2 minutes or more.

(j) Reconnect the A24 hybrid vehicle control ECU connector.

(k) Reconnect the A42 inverter with converter assembly connector.

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK

4.

CHECK HYBRID VEHICLE CONTROL ECU

(a) Disconnect the A24 hybrid vehicle control ECU connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A24-30 (HMCL) - A24-31 (HMCH)

Power switch off

80 to 170 Ω

*a

Component without harness connected

(Hybrid Vehicle Control ECU)

(c) Reconnect the A24 hybrid vehicle control ECU connector.

OK

INVERTER LOW-VOLTAGE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

REPLACE HYBRID VEHICLE CONTROL ECU

5.

CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)

CAUTION:

Be sure to wear insulated gloves.

(a) Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

(b) Disconnect the A42 inverter with converter assembly connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A42-6 (+B) - Body ground

Power switch off

10 kΩ or higher

A42-5 (+B2) - Body ground

Power switch off

10 kΩ or higher

*a

Front view of wire harness connector

(to Inverter with Converter Assembly)

(d) Reconnect the A42 inverter with converter assembly connector.

NG

GO TO STEP 7

OK

6.

REPLACE INVERTER WITH CONVERTER ASSEMBLY

Click here 2019 - 2020 MY Avalon HV [04/2018 - 08/2020]; HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER: REMOVAL

NEXT

REPLACE FUSE (PCU)

7.

REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (PCU)