(a) Apply auxiliary battery voltage to the vanity light assembly and check that the light illuminates.
OK:
Measurement Condition
|
Specified Condition
|
Auxiliary battery positive (+) → 4 (B)
Auxiliary battery negative (-) → 2 (E)
|
Vanity light illuminates
|
If the result is not as specified, replace the vanity light assembly.
|
|
*a
|
Component without harness connected
(Vanity Light Assembly)
|
|
|