Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001TFVO |
Model Year Start: 2021 |
Model: Camry HV |
Prod Date Range: [10/2020 -
] |
Title: A25A-FXS (BATTERY / CHARGING): CHARGING SYSTEM: ON-VEHICLE INSPECTION; 2021 - 2024 MY Camry HV [10/2020 - ] |
ON-VEHICLE INSPECTION
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced when inspecting auxiliary battery are shown below.
Necessary Procedure After Parts Removed/Installed/Replaced
Replacement Part or Procedure
|
Necessary Procedure
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Auxiliary battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane Tracing Assist System
|
|
Pre-collision System
|
Lighting System (w/ AFS)(EXT)
|
Memorize steering angle neutral point
|
Parking Assist Monitor System
|
|
Panoramic View Monitor System
|
|
PROCEDURE
1. CHECK AUXILIARY BATTERY
(a) Check that the auxiliary battery cables are connected to the correct terminals.
If they are not, connect them properly.
(b) Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
2. CHECK AUXILIARY BATTERY VOLTAGE
(a) Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
(b) Measure the auxiliary battery voltage according to the value(s) in the table below.
Tester Connection
|
Condition
|
Specified Condition
|
Result
|
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal
|
20°C (68°F), Power switch off
|
12.0 V or higher
|
Auxiliary battery is OK
|
12.0 V or less
|
Recharge auxiliary battery
|
3. RECHARGE AUXILIARY BATTERY
(a) Recharge the auxiliary battery.
HINT:
-
Recharge the auxiliary battery according to the charger's instructions.
-
Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.
Charge Method
|
Charging Current
|
Normal
|
Below 5 A
|
Quick
|
Below 15 A
|
(b) Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
(c) Measure the auxiliary battery voltage according to the value(s) in the table below.
Tester Connection
|
Condition
|
Specified Condition
|
Result
|
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal
|
20°C (68°F), Power switch off
|
12.0 V or higher
|
Auxiliary battery is OK
|
12.0 V or less
|
Recharge auxiliary battery
|
4. CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
(a) Check that the auxiliary battery terminals are not loose or corroded.
Torque:
Positive (+) Auxiliary Battery Terminal :
5.4 N·m {55 kgf·cm, 48 in·lbf}
Negative (-) Auxiliary Battery Terminal :
5.4 N·m {55 kgf·cm, 48 in·lbf}
If a terminal is loose or corroded, tighten or clean the terminal.
(b) Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.
Standard Resistance:
Below 1 Ω
If the result is not as specified, replace the fusible link or fuse as necessary.
5. CHECK AMD TERMINAL
(a) Remove the service plug grip.
Click here
(b) Check that the AMD terminal is connected securely, and there is no contact problem.
If there are any arc marks, replace the affected parts.
(c) Check that the nut for the AMD terminal is tightened to the specified torque.
Torque:
Inverter with Converter Assembly Side :
10 N·m {102 kgf·cm, 89 in·lbf}
No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly Side :
8.0 N·m {82 kgf·cm, 71 in·lbf}
If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.
|
|
*a
|
Inverter with Converter Assembly Side
|
*b
|
No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly Side
|
|
|
(d) Install the service plug grip.
Click here
6. CHECK DC/DC CONVERTER FUNCTION
(a) Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.
|
|
*a
|
Probe Direction
|
*b
|
Current Flowing into Auxiliary Battery
|
|
|
(b) Turn the power switch on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.
(c) Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.
(d) Measure the current and voltage according to the value(s) in the table below.
Result:
Item
|
Tester Connection
|
Condition
|
Specified Condition
|
Current flowing from auxiliary battery
|
Positive (+) auxiliary battery cable
|
Power switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
|
0 A or less
(No current from auxiliary battery)
|
Auxiliary battery voltage
|
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal
|
12.5 to 15 V
|
|
|
*a
|
Probe Direction
|
*b
|
Current Flowing from Auxiliary Battery
|
|
|
|