Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001R417 |
Model Year Start: 2021 |
Model: Camry HV |
Prod Date Range: [10/2020 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: A/C Switch Indicator does not Turn On; 2021 - 2024 MY Camry HV [10/2020 - ] |
A/C Switch Indicator does not Turn On
|
DESCRIPTION
If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.
Symptom
|
Factor
|
A/C switch indicator does not illuminate
|
-
Air conditioning amplifier assembly malfunction
-
Air conditioning control assembly malfunction
-
A/C switch malfunction
-
A/C switch indicator malfunction (including when indicator turned off without switch operation)
-
Servo motor initialization (incomplete)
-
Mechanical locking of damper and damper link
-
Refrigerant pressure is extremely low
-
Low detected ambient temperature (including thermistor assembly malfunction)
|
PROCEDURE
1.
|
CHECK AIR CONDITIONING CONTROL ASSEMBLY
|
(a) Check that the switch indicators on the air conditioning control assembly illuminate immediately after the engine is started.
OK:
All switch indicators illuminate.
OK
|
|
|
2.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Ambient Temp Sensor
|
Thermistor assembly
|
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Thermistor assembly circuit malfunction
-
When open circuit: -23.30°C (-9.94°F)
-
When short circuit: 65.95°C (150.71°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Ambient Temp Sensor
|
OK:
The value displayed is 0°C (32°F) or higher.
|